Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
TEMPSTAR/TEMPSTAR SDS:
RINSE
TYPICAL
HEATER TOTAL
ELECTRICAL
VOLTS PH
HZ
RATINGS
AMPS
CIRCUIT
208
1
50
12KW@240V
71 A
90 AMP
208
1
50
14KW@240V
78 A
100 AMP
230
1
50
12KW@240V
78 A
100 AMP
230
1
50
14KW@240V
86 A
110 AMP
208
3
50
12KW@240V
45 A
60 AMP
208
3
50
14KW@240V
49 A
70 AMP
230
3
50
12KW@240V
48 A
60 AMP
230
3
50
14KW@240V
53 A
70 AMP
380
3
50
12KW@380V
29 A
40 AMP
380*
3
50
14KW@208V
34 A
45 AMP
415
3
50
12KW@415V
26 A
35 AMP
415
3
50
14KW@415V
29 A
40 AMP
440
3
50
12KW@460V
21 A
30 AMP
440
3
50
14KW@460V
25 A
35 AMP
208
1
60
12KW@240V
69 A
90 AMP
208
1
60
14KW@240V
76 A
100 AMP
230
1
60
12KW@240V
76 A
100AMP
230
1
60
14KW@240V
84 A
110 AMP
208
3
60
12KW@240V
43 A
60 AMP
208
3
60
14KW@240V
47 A
60 AMP
230
3
60
12KW@240V
46 A
60 AMP
230
3
60
14KW@240V
51 A
70 AMP
460
3
60
12KW@480V
22 A
30 AMP
460
3
60
14KW@480V
25 A
35 AMP
* This model is wired in a wye configuration for the heaters.
TEMPSTAR LT/TEMPSTAR NB:
RINSE
TYPICAL
HEATER TOTAL
ELECTRICAL
VOLTS PH
HZ
RATINGS
AMPS
CIRCUIT
208
1
50
N/A
28 A
35 AMP
230
1
50
N/A
30 A
40 AMP
208
3
50
N/A
20 A
25 AMP
230
3
50
N/A
21 A
30 AMP
380
3
50
N/A
10 A
15 AMP
415
3
50
N/A
10 A
15 AMP
440
3
50
N/A
8 A
15 AMP
208
1
60
N/A
26 A
35 AMP
230
1
60
N/A
28 A
35 AMP
208
3
60
N/A
18 A
25 AMP
230
3
60
N/A
28 A
35 AMP
460
3
60
N/A
8 A
15 AMP
TEMPSTAR S:
RINSE
TYPICAL
HEATER TOTAL
ELECTRICAL
VOLTS PH
HZ
RATINGS
AMPS
CIRCUIT
208
1
60
N/A
6 A
15 AMP
230
1
60
N/A
6 A
15 AMP
208
3
60
N/A
6 A
15 AMP
230
3
60
N/A
6 A
15 AMP
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is ade-
quate and meets all applicable national and local codes. These numbers are provided in this manual simply for ref-
erence and may change without notice at any given time.
Summary of Contents for Upright Door Dishmachines Tempstar Series
Page 2: ......
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 16: ...8 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 22: ...14 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 24: ...16 SECTION 4 TROUBLESHOOTING SECTION...
Page 27: ...19 SECTION 5 PARTS SECTION...
Page 67: ...59 SECTION 6A ELECTRICAL SCHEMATICS FOR TOP MOUNT UNITS...
Page 83: ...75 SECTION 6B ELECTRICAL SCHEMATICS FOR SIDE MOUNT UNITS...
Page 93: ...85 SECTION 6C ELECTRICAL SCHEMATICS FOR OPTIONS...
Page 96: ...88 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS...
Page 103: ......