OPERATING INSTRUCTIONS
OPERATION
For the first operation of each day, it might be necessary to run the machine through
three cycles to ensure that all of the cold water is out of the system and to verify
that the machine is operating correctly. To cycle the machine, ensure that the power
is on and that the tub has filled to the correct level. Lift and close the door and the
cycle light will illuminate. The machine will start, run through the cycle, and shut-off
automatically. Repeat this two more times. The machine is now ready.
To wash a rack, open the door completely (avoiding hot water that might drip from
the door) and slide the rack into the machine.
Close the door and the machine will start automatically. Once the cycle is complete,
open the door and remove the rack of clean ware. Replace with a rack of soiled
ware and close the door. Repeat this process.
Based on use, the scrap screen might become clogged with soil and debris as the
workday progresses. Operators should regularly inspect the scrap screen to ensure
it has not become clogged. If clogged, it will reduce the washing capability of the
machine. Instruct operators to clean-out the scrap screen at regular intervals or as
required by workload. Do NOT beat strainers to remove debris.
1. Turn machine off by flipping the power switch to “OFF.”
2.
Open the door and allow steam/heat to escape.
3.
Remove the standpipe and allow the tub to drain.
WARM-UP CYCLES
WASHING A RACK
OF WARE
OPERATIONAL
INSPECTION
SHUTDOWN &
CLEANING
!
WARNING
WARNING!
Wash tank
water will be hot!
Summary of Contents for TempStar Series
Page 31: ...23 07610 003 61 42 V CONTROL BOX PARTS 10 9 13 14 15 12 11 27 41 42 40 25 21 21 21 22 22...
Page 62: ...07610 003 61 42 V 54 PARTS VER SYSTEM 18 24 23 12 11 16 17 14 21 22 20 19 27 28 29...
Page 68: ...07610 003 61 42 V 60 SCHEMATICS TEMPSTAR VER 208 230 V NEW RINSE TANK...
Page 69: ...61 07610 003 61 42 V SCHEMATICS TEMPSTAR VER 460 V NEW RINSE TANK...
Page 70: ...07610 003 61 42 V 62 SCHEMATICS TEMPSTAR VER 208 230 V OLD RINSE TANK...
Page 71: ...63 07610 003 61 42 V SCHEMATICS TEMPSTAR VER 460 V OLD RINSE TANK...
Page 72: ...07610 003 61 42 V 64 SCHEMATICS NB 208 230 V...
Page 73: ...65 07610 003 61 42 V SCHEMATICS NB 460 V...
Page 74: ...07610 003 61 42 V 66 SCHEMATICS STEAM 208 230 V...