11
07610-003-61-42-V
INSTRUCTIONS
INSTALLATION
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
The data plate is located on the right side of the machine. Refer to the data plate for
machine operating requirements, machine voltage, total amperage, and serial number.
1. Open the control box by using a phillips screwdriver to remove the four screws on
the front cover of the control box.
2.
Install 3/4” conduit into the pre-punched holes in the back of the control box.
3.
Route power wires and connect to power block and grounding lug.
4. Install the service wires (L3 for 3-Phase only) to the appropriate terminals as they
are marked on the terminal block.
5. Install the grounding wire into the lug provided.
6. Tighten the connections.
“DE-OX” or similar anti-oxidation agent should be used on all power
connections.
CAUTION!
Improperly connecting external devices can cause damage to the
machine and/or electrical infrastructure! Click
here
for a wiring guide.
On 3-Phase machines only, correct pump motor rotation must be verified before
the machine is operated. Failure to do so can result in damage to the machine and
components.
1.
Follow the "Filling the Wash Tub" section.
2. Locate the wash pump motor and identify the arrow decal which shows the
correct motor rotation (if no decal is present, correct rotation is away from the
pump volute).
3. Flip the mode switch to "MANUAL" and start the machine.
4.
Observe the rotation of impeller and quickly stop the machine.
5. If rotation is incorrect, disconnect electrical power and reverse the L1 and L2
connections at terminal block shown in the section above.
ELECTRICAL POWER
CONNECTIONS
Disconnect electrical
power supplies and
lockout/tagout in
accordance with
appropriate procedures
and codes at the
disconnect switch.
MOTOR ROTATION
!
CAUTION
i
Imbalanced
wild leg goes
to L3.
NOTICE
L1
L2
L3
Ground
3
Φ
NOTICE
CAUTION!
On 3-Phase
machines only, correct
pump motor rotation
must be verified
before operation!
!
CAUTION
If necessary, see
"Heaters" page for
phase conversion kit.
Pump Volute
Impeller
Summary of Contents for TempStar Series
Page 31: ...23 07610 003 61 42 V CONTROL BOX PARTS 10 9 13 14 15 12 11 27 41 42 40 25 21 21 21 22 22...
Page 62: ...07610 003 61 42 V 54 PARTS VER SYSTEM 18 24 23 12 11 16 17 14 21 22 20 19 27 28 29...
Page 68: ...07610 003 61 42 V 60 SCHEMATICS TEMPSTAR VER 208 230 V NEW RINSE TANK...
Page 69: ...61 07610 003 61 42 V SCHEMATICS TEMPSTAR VER 460 V NEW RINSE TANK...
Page 70: ...07610 003 61 42 V 62 SCHEMATICS TEMPSTAR VER 208 230 V OLD RINSE TANK...
Page 71: ...63 07610 003 61 42 V SCHEMATICS TEMPSTAR VER 460 V OLD RINSE TANK...
Page 72: ...07610 003 61 42 V 64 SCHEMATICS NB 208 230 V...
Page 73: ...65 07610 003 61 42 V SCHEMATICS NB 460 V...
Page 74: ...07610 003 61 42 V 66 SCHEMATICS STEAM 208 230 V...