SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
TEMPSTAR HH:
RINSE
TYPICAL
HEATER
TOTAL ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
415
3
60
12KW
28 A
35 AMP
415
3
60
14KW
30 A
40 AMP
208
1
60
12KW@240V
75 A
100 AMP
208
1
60
14KW@240V
82 A
110 AMP
230
1
60
12KW@240V
81 A
110 AMP
230
1
60
14KW@240V
90 A
125 AMP
208
3
60
12KW@240V
48 A
60 AMP
208
3
60
14KW@240V
52 A
70 AMP
230
3
60
12KW@240V
52 A
70 AMP
230
3
60
14KW@240V
57 A
80 AMP
460
3
60
12KW@480V
24 A
30 AMP
460
3
60
14KW@480V
26 A
35 AMP
TEMPSTAR HH NB:
RINSE
TYPICAL
HEATER
TOTAL ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
208
1
60
N/A
31 A
35 AMP
230
1
60
N/A
33 A
35 AMP
208
3
60
N/A
23 A
25 AMP
230
3
60
N/A
24 A
35 AMP
460
3
60
N/A
10 A
15 AMP
TEMPSTAR HH S:
RINSE
TYPICAL
HEATER
TOTAL ELECTRICAL
VOLTS
PH
HZ
RATINGS
AMPS
CIRCUIT
208
1
60
N/A
12 A
15 AMP
230
1
60
N/A
12 A
15 AMP
208
3
60
N/A
12 A
15 AMP
230
3
60
N/A
12 A
15 AMP
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
Summary of Contents for TempStar HH
Page 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 14: ...7 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 20: ...13 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 22: ...15 SECTION 4 TROUBLESHOOTING ...
Page 25: ...18 SECTION 5 PARTS SECTION ...
Page 54: ...47 SECTION 6 ELECTRICAL SCHEMATICS ...
Page 68: ...61 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 75: ......