![Jackson DISHSTAR HT-E Installation, Operation And Service Manual Download Page 34](http://html.mh-extra.com/html/jackson/dishstar-ht-e/dishstar-ht-e_installation-operation-and-service-manual_628865034.webp)
27
07610-004-43-79-Q
Rinse water runs
continuously
with breaker
turned off.
1. Defective plunger in solenoid valve.
2. Defective diaphragm in solenoid valve.
1. Replace plunger.
2. Replace diaphragm.
Wash
temperature not
within range.
1. Water level low.
2. RTD setpoint too low.
3. Defective RTD.
4. Wash heater defective.
5. Defective heater contactor R1.
1. Check water level. If low, run new fill cycle.
2. Adjust setpoint.
3. Replace RTD.
4. Replace heater element.
5. Replace contactor.
Rinse
temperature not
within range.
1. RTD is defective.
2. Incoming rinse water does not
meet minimum criteria indicated
machine data plate.
3. Rinse heaters damaged.
4. Setpoint screens set low.
1. Replace if necessary.
2. Adjust as required.
3. Check amperages. Replace if necessary.
4. Adjust rinse tank setpoint.
Machine
doesn’t drain
when power
button is
pressed.
1. Drain clogged.
2. Defective drain valve.
1. Remove obstruction.
2. Replace.
Incorrect water
pressure
displayed
during Fill or
Rinse.
1. Water turned off.
2. Transducer disconnected.
3. Pressure transducer defective.
1. Turn water on.
2. Verify wiring.
3. Replace pressure transducer.
TROUBLESHOOTING
TROUBLESHOOTING
OBSERVATION POSSIBLE CAUSE
REMEDY
WARNING!
Inspection, testing, and repair of electrical equipment should only be performed by qualified
service personnel. Certain procedures in this section require electrical tests or measurements while power is
applied to machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect
power, attach test equipment, and reapply power to test. When replacing electrical parts, disconnect power at
circuit breaker.
!
WARNING
i