10
After filling the heater tank, the heater element must be enabled. The machine is
shipped from the factory with the heater element disabled. This is done to ensure
that the heater element is not damaged by energizing the element without the
element being submerged in water. To enable the heater element:
1. Disconnect electrical power and remove the control box cover.
2.
Connect the tagged white/blue wires.
3.
Replace the control box cover and reconnect electrical power.
4. Press the ON/OFF button. The heater element will energize to sustain water
temperature.
If the water level is not between the lines on the drain stopper, it will require
adjustment. Check to ensure that the recommended water pressure is being
supplied to the machine ( 20
A
5 PSI). If the water pressure is correct, the timer
needs adjustment. Use the following steps to adjust the fill time:
1. Remove control box cover.
2. Adjust the left side of CAM 4. To raise the water level, increase (open) the notch
of the CAM; to lower the water level, decrease (close) the notch of the CAM.
3. Press and hold START button until the cycle starts (about two seconds), run
a cycle, then check the water level.
4. Adjust as necessary then replace the control box cover.
The machine runs a complete cycle to drain and fill. If the machine fails to drain, the
water will build-up inside the tub. After the initial fill, the rinse water for the current
cycle will mix with the wash water for the next cycle.
INSTRUCTIONS
OPERATION
INITIAL
START-UP
CAUTION!
Water must
be in the sump while the
machine is running to
avoid running the pump
dry and causing damage
to the pump seal.
!
CAUTION
Disconnect electrical
power at the breaker or
disconnect switch and
tag-out in accordance with
procedures and codes.
CYCLE
WASH
DRAIN
FILL
SANI
DET
RINSE
AID
SPARE