07610-002-10-23-U
21
DELIME NORMAL
1.
Flip “OFF/ON/FILL” switch to the “ON” position.
2.
Close door and hold the “OFF/ON/FILL” switch in the “FILL “ position for
approximately 8-10 seconds.
3.
Water must be between two lines on drain stopper.
4.
Add deliming solution per chemical supplier’s instructions.
5. Close door.
6.
Flip the NORMAL/DELIME switch on the back of the control box to DELIME.
7. Run machine period of time recommended by chemical supplier.
8.
Wait five minutes, then inspect inside of the machine. If the machine is not
delimed, run again.
9.
Flip the NORMAL/DELIME switch to NORMAL.
10. Run two cycles to remove residual deliming solution.
11.
Drain and re-fill the machine.
CAUTION!
This equipment is not recommended for use with deionized water or
other aggressive fluids. Use of deionized water or other aggressive fluids will result
in corrosion and failure of materials and components. Use of deionized water or
other aggressive fluids will void the manufacturer’s warranty.
OPERATING INSTRUCTIONS
OPERATION
DELIMING
!
CAUTION