SECTION 5: PARTS SECTION

36

RINSE ARM & WASH ARM ASSEMBLIES

Washer, Rinse Arm
05330-011-42-10

O-ring (Not Shown)

05330-002-60-69

Rinse Arm
05700-031-38-30

Plug, Rinse Arm
04730-609-04-00

Bushing, Rinse Head

05700-021-33-84

Bearing

03120-002-72-24

Ring, Retaining 

05340-112-01-11

Wash Arm Weldment w/ Plugs

05700-021-46-58

Bearing Assembly
05700-021-35-97

O-ring (Not Shown)
05330-002-60-69

Wash Arm Assembly

2 per Avenger

LT

1 per Avenger

HT

05700-021-39-23

Rinse Arm Assembly

(AVENGER

HT units only)

2 per Asm.

05700-031-39-21

Summary of Contents for Avenger HT

Page 1: ...FOR JACKSON MODELS Avenger HT Avenger LT Jackson MSC LLC P O BOX 1060 HWY 25E BARBOURVILLE KY 40906 PHONE 606 523 9795 FAX 606 523 9196 www jacksonmsc com AVENGER UNDERCOUNTER DISHMACHINE SERIES September 18 2009 P N 7610 003 34 01 Revision D ...

Page 2: ...ion if serial number has been removed or altered or if unit is used for purpose other than it was origi nally intended TRAVEL LIMITATIONS Jackson MSC limits warranty travel time to 2 two hours and mileage to 100 one hundred miles Jackson MSC will not pay for travel time and mileage that exceeds this or any fees such as those for air or boat travel without prior authorization WARRANTY REGISTRATION ...

Page 3: ...PRODUCT FAILURE TO DO SO WILL VOID THE WARRANTY LLAME AL 1 888 800 5672 PARA REGISTRAR ESTE PRODUCTO AL NO HACERLO LA GARANTIA SERA ANULADA S V P APPELER 1 888 800 5672 POUR ENREGISTRER CE PRODUIT LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON ENREGISTREE ...

Page 4: ...w color scheme 29 08 06 07 MAW 7930 Updated AvengerHT Incoming plumbing assembly C 10 07 07 MAW PROCESS Added Avenger LTH designation Added 480 Volt Avenger HT 11 20 07 MAW Process Corrected 480 Volt Avenger HT components PG 47 48 01 31 08 MAW Process Updated installation instructions Replaced LTH with LT designa tion Added vacuum switch assembly ...

Page 5: ...C LLC provides technical support for all of the dishmachines detailed in this manual We strongly recommend that you refer to this manual before making a call to our technical support staff Please have this manual with you when you call so that our staff can refer you if necessary to the prop er page Technical support is available from 8 00 a m to 5 00 p m EST Monday through Friday Technical suppor...

Page 6: ...ent Avenger LT 23 Terminal Block Box Assembly 24 Chemical Feeder Pump Assembly Avenger HT 25 Chemical Feeder Pump Assembly Avenger LT 27 Chemical Feeder Pump Components 29 Incoming Plumbing Assembly Avenger HT 30 Incoming Plumbing Assembly Avenger LT 31 Solenoid Valve Repair Kit Vacuum Breaker Repair Kit 32 Water Pressure Regulator Kit WPRK Option 32 Wash Motor Drain Plumbing Assembly 33 Avenger L...

Page 7: ...1 SECTION 1 SPECIFICATION INFORMATION ...

Page 8: ... In some cases this may automatically extend the wash cycle time ELECTRICAL REQUIREMENTS WASH MOTOR HP 3 4 NOTE Typical Electrical Circuit is based upon 1 125 of the full amperage load of the machine and 2 typical fixed trip cir cuit breaker sizes as listed in the NEC 2002 Edition Local codes may require more stringent protection than what is dis played here Always verify with your electrical serv...

Page 9: ...LORINE REQUIRED PPM 50 ELECTRICAL REQUIREMENTS WASH MOTOR HP 3 4 NOTE Typical Electrical Circuit is based upon 1 125 of the full amperage load of the machine and 2 typical fixed trip cir cuit breaker sizes as listed in the NEC 2002 Edition Local codes may require more stringent protection than what is dis played here Always verify with your electrical service con tractor that your circuit protecti...

Page 10: ... dimensions from floor can be increased 1 with adjustable feet supplied WALL 141 2 368mm DISH CLEARANCE 253 8 644mm 165 8 423mm 1 9 16 40mm A 11 4 32mm B 233 4 604mm A BACK B 41 8 105mm 111 2 292mm 7 8 22mm 3 5 16 84mm 1 4 6mm Minimum C Wall Clearance Avenger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Revised N A SECTION 1 SPECIFICATION INFORMATION Avenger HT DIMENSIONS 4 All dimensi...

Page 11: ...re than 24 AFF All dimensions from floor can be increased 1 with adjustable feet supplied Door Open TOP WALL 253 8 644mm 165 8 423mm 1 9 16 40mm A 11 4 32mm B 233 4 604mm BACK B 31 2 89mm 111 2 292mm A 4 5 16 110mm 1 4 6mm Wall Clearance C Minimum Avenger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Revised N A SECTION 1 SPECIFICATION INFORMATION Avenger LT DIMENSIONS 5 All dimensions ...

Page 12: ...6 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...

Page 13: ...ormed to deter mine if the HTS 11 scale prevention and corrosion control need to be installed A hardness test kit is attached to the warning tag that is attached to the incoming plumbing connection on the back of the machine If the hardness is higher than 5 GPG the HTS 11 will need to be installed please contact Jackson immediately to have this item shipped to you WATER SUPPLY CONNECTION FOR MACHI...

Page 14: ...al Code ANSI NFPA 70 latest edition and or other electrical codes Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit The data plate is located toward the right front side of the dishmachine Refer to the data plate for machine operating requirements machine voltage total amperage load and serial number To install the incoming ...

Page 15: ...t installed or if for some reason the chemical lines have been removed and air is allowed to enter CAUTION Water must be in the sump and wash tank prior to the dispensing of chemicals Sanitizer in concentration is caustic and may cause damage without dilution 1 Verify that the proper chemical tube stiffener inlet is in the proper container 2 Use the prime switches located on the control panel at t...

Page 16: ...me is in seconds In the time categories each second in use will light up To deselect the option press ENTER and the light will go off press ENTER again and it will illuminate Once you have set your time category press the MOVE button until the ACCEPT light illuminates and press ENTER This will save the changed parameters Once you press the ENTER button when the ACCEPT light is blinking you will ex...

Page 17: ...be used per cycle Talk with your water treatment specialist and detergent vendor and come up with a complete training program for operators Using too much detergent has as detrimental effects as using too little The proper amount of detergent must be used for job It is important to remember that certain menu items may require extra detergent by their nature and personnel need to be made aware of t...

Page 18: ... important to remember that a dishmachine is not a garbage disposal and that simply throwing unscraped dishes into the machine simply defeats the purpose altogether of washing the ware Scraps should be removed from ware prior to being loaded into a rack Pre rinsing and pre soaking are good ideas especially for silverware and casserole dishes Place cups and glasses upside down in racks so that they...

Page 19: ...emove lime and corrosion deposits on a frequent basis A deliming solution should be available from your detergent supplier Read and follow all instructions on the label of the deliming solution NOTE If this machine is equipped with a HTS 11 scale prevention and corrosion control device and lime is becoming a fre quent problem the cartridge needs to be replaced To order a replacement cartridge call...

Page 20: ...14 SECTION 3 PREVENTATIVE MAINTENANCE ...

Page 21: ...nce of your machine Hard water makes dishmachines work harder and decreases efficiency Again it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larg er problems or even cause harm to the operator If a problem is discovered secure the dishmachine using proper shut down procedures as listed in this manual and contact a QUALIFIED SERVICE...

Page 22: ...16 SECTION 4 TROUBLESHOOTING ...

Page 23: ...nect or replace wires in motor 2 Defective manual wash switch Replace 3 Defective motor starting relay Replace Problem Motor operates on manual wash but not on automatic 1 Defective circuit in manual wash switch Replace switch Problem No water comes through the rinse arms when the ON FILL switch is depressed 1 Water not turned on Turn water on 2 Defective solenoid valve Replace solenoid valve Prob...

Page 24: ... circuit breaker Problem Rinse water not at required temperature range 1 Check that orange white wires are connected See note in installation instructions 2 Thermometer is defective Replace 3 Thermostat is defective Adjust the thermostat Replace if necessary 4 Incoming rinse water does not meet minimum criteria indicated on machine data plate Adjust as required Problem Machine doesn t drain when O...

Page 25: ...19 SECTION 5 PARTS SECTION ...

Page 26: ...0 Relay 240V 05945 111 89 75 Screw 6 32 x 3 8 05305 002 25 91 Locknut 10 24 w Nylon Insert 1 per Asm 05310 373 01 00 P Clamp 1 4 05975 002 61 42 Locknut 6 32 w Nylon Insert 05310 373 03 00 Complete Control Panel Weldment Assembly Avenger HT 05700 003 31 47 Complete Control Panel Weldment Assembly Avenger LT 05700 003 46 74 Unless specified here other components are the same as above Avenger HT Com...

Page 27: ...ral 05945 003 33 09 4 1 Relay 05945 002 47 41 5 1 Terminal Board 05940 021 94 85 6 1 Track Terminal Block 05700 003 37 49 7 1 Fuse Holder 05920 011 72 89 8 1 Fuse 1 4 AMP 05920 002 75 95 9 2 Contactor 05945 111 60 07 10 1 Overload 05945 111 60 08 11 2 Screw 6 32 x 3 8 w External T Washer 05305 002 25 91 12 1 Open Closed Bushing 875 05975 003 35 21 13 6 Screw 10 32 x 3 8 Long Phil Truss Head 05305 ...

Page 28: ...Light Amber 05945 111 44 44 4 1 Thermometer 96 Wash 06685 111 68 49 5 1 Light Red 05945 111 44 45 6 1 Window Plug 05975 003 31 72 7 1 Switch Rinse Aid 05930 011 49 54 8 1 Switch Detergent 05930 011 49 54 9 1 Light Green 05945 111 44 43 10 1 Switch On Off 05930 301 49 00 11 1 Gauge 0 100 PSI with Green Zone 06680 011 86 42 1 Bell Adapter 1 4FNPT x 1 8 FNPT 04730 003 33 02 1 Hose Pressure Gauge 0473...

Page 29: ...0 011 80 40 1 Decal Prime Switch 09905 011 49 52 4 Locknut 6 32 Hex w Nylon Insert 05310 373 03 00 4 1 Light Red 05945 111 44 45 5 1 Light Amber 05945 111 44 44 6 1 Light Green 05945 111 44 43 7 1 Counter 115V 05990 111 35 38 2 Screw 4 40 x 1 4 Phillips Pan Head 05305 002 32 38 8 1 Switch Auto Manual 05930 301 49 00 9 1 Switch On Off 05930 011 49 55 10 3 Switch Peripump 05930 011 49 54 11 2 Buzzer...

Page 30: ... 011 62 72 Terminal Block Box 05700 003 27 69 Terminal Block Box Cover Not Shown 05700 003 27 70 Decal Power Connections 09905 011 47 35 Terminal Block Track 05700 000 43 60 Locknut 10 24 S S Hex w Nylon Insert 05310 373 01 00 Screw 10 32 x 1 2 05305 011 39 36 Screw 10 32 x 1 2 05305 011 39 36 Terminal Block 2 Per 3 per 480V 05940 500 02 19 Ground Lug 05940 200 76 00 ...

Page 31: ...7 2007 Revised N A SECTION 5 PARTS SECTION CHEMICAL FEEDER PUMP ASSEMBLY AVENGER HT 25 2 3 5 1 15 16 Complete Chemical Feeder Pump Assembly 05700 003 32 03 4 7 12 13 14 10 11 6 9 8 See page 39 for indi vidual peri pump com ponents A B C D A B C D A B C D A B D ...

Page 32: ... 1 Motor 36 RPM 115V 480V Machine 04320 111 35 14 3 1 Rinse Aid Feeder Pump Black Roller 14RPM 240V 05700 002 72 48 3 1 Motor 14 RPM 115V 480V Machine 04320 111 35 13 4 2 Nylon Loop Strap 04320 002 71 22 5 2 Locknut 6 32 W Nylon Insert 05310 373 03 00 6 1 Red Tube 1 4 x 14 1 2 05700 003 33 59 7 1 Tube Tygoprene 3 16 x 8 05700 003 22 89 8 1 Red Tube 1 4 x 72 05700 003 33 58 9 1 Red Tube 1 4 x 120 0...

Page 33: ...Avenger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Revised N A SECTION 5 PARTS SECTION CHEMICAL FEEDER PUMP ASSEMBLY AVENGER LT 27 ...

Page 34: ... PVDF 04730 003 36 14 12 4 5 16 ID Clear Tube 05700 003 53 26 13 1 Red Tube 1 4 x 100 05700 003 03 45 14 1 White Tube 1 4 x 100 05700 003 20 67 15 1 Blue Tube 1 4 x 48 05700 002 62 11 16 1 Blue Tube 1 4 x 100 05700 003 20 68 17 1 Red Tube 1 4 x 48 05700 002 62 12 18 1 White Tube 1 4 x 48 05700 002 62 13 19 Tye Wrap 05945 602 01 16 Avenger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Re...

Page 35: ...28 Front Housing 04320 111 37 08 Rear Housing 04320 111 37 09 Tygoprene Tube 05700 03 22 89 Screw 8 32 x 1 2 Phillips Flat Head 2 per 05305 011 37 06 Motor 14 RPM 115V Rinse Aid Feeder Pump 04320 111 35 13 Motor 14 RPM 240V Rinse Aid Feeder Pump 04320 111 47 46 Motor 36 RPM 115V Detergent Sanitizer Feeder Pump 04320 111 35 14 Motor 36 RPM 240V Detergent Sanitizer Feeder Pump 04320 111 47 47 Screw ...

Page 36: ...rass 2 per machine 04730 209 01 00 Clamp Pipe 05700 011 38 62 Clamp Pipe 2 per assembly 05700 000 35 05 Clamp Hose 04730 719 06 09 Injector Hose 3 4 x 7 1 2 05700 003 33 49 Connects to Rinse Injector Connects to Rinse Stiffener Rinse Stiffener Not replaceable part of the tub weldment Injector Hose Spring 05340 003 33 50 Locknut 1 4 20 S S Hex with Nylon Insert 05310 374 01 00 Locknut 1 4 20 S S He...

Page 37: ...0 000 35 05 Connects to 45 Deg Elbow Clamp Hose 04730 719 06 09 Injector Hose 3 4 x 11 05700 003 29 68 Gasket Rinse 05330 111 42 81 Plate Deflector 05700 002 62 49 Plate Rinse 05700 011 82 86 Plate Rinse Weldment 05700 011 82 73 Complete Incoming Plumbing Assembly 05700 003 34 67 Vacuum Breaker 04820 003 06 13 Elbow 45 Deg 1 2 NPT x 3 4 Hose 04730 003 29 22 Gasket Rinse 05330 111 42 81 Locknut 1 4...

Page 38: ...ly 1 2 06401 003 07 44 Screw Data Plate Coil Housing Valve Bonnet Spring Plunger Kit 06401 003 07 40 Spring position is moved for clarity Goes below the plunger O Ring Diaphragm 06401 003 07 41 Diaphragm Retainer Screen Retainer Mesh Screen Valve Body Components of Repair Kit 06401 003 06 23 Cap Screw Data Plate Cap O Ring Plunger Body Cap Retainer Complete Vacuum Breaker Assembly 1 2 NPT 04820 00...

Page 39: ...H MANIFOLD ASSEMBLY 2 1 3 4 4 5 6 4 See Motor and Pump Assembly Page 14 9 9 10 11 12 13 Ball Valve Assembly AVENGER LT 115V AVENGER HT 480V 04730 003 34 60 AVENGER HT 240V 04730 003 33 64 15 9 4 7 8 For the Avenger LT replace item 1 below with this manifold Area within this box is an overall view of the Avenger LT wash manifold assembly 18 16 1a 17 19 ...

Page 40: ...05310 374 01 00 9 3 Clamp 3 16 to 1 1 2 04730 719 06 09 10 1 Hose 8 Straight Drain 04720 003 27 95 11 1 Hosebarb 1 x 3 4 NPT Polypropylene 04730 011 65 86 12 1 Spacer Drain Valve 05700 003 31 93 13 1 Bracket Drain Valve Support 05700 003 31 74 14 1 Hose 1 I D x 10 Feet Long 05700 011 39 72 15 1 Hosebarb 90 1 x 3 4 NPT 04730 011 65 87 16 2 O ring Manifold 05330 111 35 15 17 1 Tube Wash Manifold 057...

Page 41: ...Case Capscrew 05305 002 81 88 Hardware Bolt 3 8 16 x 1 2 per 05305 276 03 00 Lockwasher 3 8 2 per 05311 276 01 00 Nut Hex 3 8 16 2 per 05310 276 01 00 Motor Only 208 230V 60 HZ 06105 002 79 61 Motor Only 460V 60 HZ 06105 003 52 64 Complete Pump Motor Assembly 60 HZ With Bracket 05700 003 31 57 Complete Pump Motor Assembly 60 HZ No Bracket 06105 002 72 75 Pump Only Assembly 60 HZ Area indicated wit...

Page 42: ...60 69 Rinse Arm 05700 031 38 30 Plug Rinse Arm 04730 609 04 00 Bushing Rinse Head 05700 021 33 84 Bearing 03120 002 72 24 Ring Retaining 05340 112 01 11 Wash Arm Weldment w Plugs 05700 021 46 58 Bearing Assembly 05700 021 35 97 O ring Not Shown 05330 002 60 69 Wash Arm Assembly 2 per Avenger LT 1 per Avenger HT 05700 021 39 23 Rinse Arm Assembly AVENGER HT units only 2 per Asm 05700 031 39 21 ...

Page 43: ...ter 208 230 Volt 04540 111 43 21 480 Volt 04540 002 29 82 Fitting 1 4 Imperial Brass 05310 924 02 05 Nut 5 16 18 S S Hex 05310 275 01 00 Lockwasher 5 16 Split 05311 275 01 00 Locknut 1 4 20 S S Hex with Nylon Insert 05310 374 01 00 Complete Rinse Tank Assembly AVENGER HT 208 230V 05700 003 31 94 Complete Rinse Tank Assembly AVENGER HT 480V 05700 003 37 78 Thermostat 05930 003 06 48 Dielectric Cove...

Page 44: ...07 2007 Revised N A SECTION 5 PARTS SECTION AVENGER LT THERMOSTAT HEATER COMPONENTS 38 Hi Limit Thermostat 06685 003 46 77 Heater Fire Bar 04540 003 46 27 Insulation Paper 1 8 04540 003 46 30 Heater Cover Plate 05700 003 46 37 Wash Thermostat 05930 003 13 65 ...

Page 45: ...venger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Revised N A SECTION 5 PARTS SECTION 39 DOOR ASSEMBLY 5 12 15 16 14 13 3 1 17 4 18 19 9 7 2 8 10 11 6 Complete Door Assembly 05700 003 32 09 ...

Page 46: ... Hinge Left Weldment 05700 003 32 71 13 6 Screw 1 4 20 x 1 1 2 Flat Phillips Head 05305 011 44 50 14 2 Hinge Spacer 05700 003 33 42 15 2 Stop Door Hinge 05700 003 32 55 16 2 Screw No 10 Pan Head 18 8 S S x 1 2 05305 173 01 00 17 2 Retaining Plate Assembly 05700 011 44 37 18 1 Magnet Reed Switch 05930 002 68 53 19 2 Locknut 6 32 S S Hex with Nylon Insert 05310 373 03 00 Avenger Series Technical Man...

Page 47: ...700 003 32 32 Cover Right HInge Weldment 05700 002 18 42 Hinge Components secured with Locknut 1 4 20 S S Hex with Nylon Insert 05310 374 01 00 Cover Left Hinge Weldment 05700 002 18 41 Switch Mounting Plate Assembly 05700 003 33 54 HInge Stop Weldment Right Shown 05700 003 32 63 Left 05700 003 32 61 Door Switch Bracket Assembly 05700 003 32 21 Door Switch 05930 003 31 44 Door Switch Bracket 05700...

Page 48: ...om Panel 05700 003 37 87 The swivel feet used on the frames may be ordered using 05340 108 02 00 Hardware Nut 1 4 20 Serrated Hex 4 per Asm 05310 011 66 49 Nut 5 16 18 Cad Spline 4 per Asm 05310 959 03 00 Shroud Plug 2 per unit 05700 003 32 50 Standard Back Panel 05700 003 36 35 Optional Back Panel 05700 003 33 55 W Left Shroud 05700 003 37 04 W Top Shroud 05700 003 37 06 W Right Shroud 05700 003 ...

Page 49: ...LANEOUS PARTS 43 Rail Left Rack 05700 031 37 89 Rail Right Rack 05700 031 37 88 Strainer Spacer 05700 001 35 83 Attaches with Nut Nylon Wing 1 4 20 05310 994 01 00 Strainer Weldment 05700 003 32 81 Components secured with Locknut 1 4 20 S S Hex with Nylon Insert 05310 374 01 00 Splash Shield 05700 003 33 51 ...

Page 50: ...and Assembly 05700 003 34 25 Stand 05700 002 88 82 18 Leg 05700 002 89 47 Cross Brace 05700 003 25 90 Bullet Foot 05340 108 01 03 Cross Member Bracket 04730 003 25 89 Installation Instructions To install the stand first remove the adjustable feet from the machine Place machine on table and use the square mounting holes to line up the machine Re insert adjustable feet through bottom of table top an...

Page 51: ...nstalled vertically The provided bracket is to be secured to the wall Observe proper inlet outlet water directions Flow directions are mold ed into the top of the head Line pressure should be released prior to changing cartridges De liming of equipment prior to installation is recommended but not required Replacement Cartridge Inspect at least every 6 months 04730 003 28 04 Replacement Test Strip ...

Page 52: ...Ring 05330 002 81 83 5 1 Door Switch Reed 05930 003 31 44 6 1 Relay 220 240 Volt 05945 111 89 75 7 1 Relay 115 Volt 05945 002 47 41 8 2 Switch Det Rinse Aid Prime 05930 011 49 54 9 2 Switch On Off 05930 301 49 00 10 2 Switch Auto Manual 05930 011 49 55 11 1 Fill Solenoid Valve 1 2 04810 100 09 18 12 1 Vacuum Breaker 04820 003 06 13 13 1 Timer Universal 05945 003 33 09 14 4 Washer Rinse Arm 05330 0...

Page 53: ... x 394 Liquid Tite 05975 011 49 03 4 2 Switch Pressure 06685 003 36 13 5 2 Bracket Pressure Switch 05700 003 53 03 6 2 Locknut 10 32 S S Hex w Nylon Insert 05310 373 02 00 7 2 Screw 10 32 x 3 8 Long 05305 173 12 00 8 2 Wye 1 4 Barbed 04730 003 36 14 9 6 Tubing Tygoprene 1 Long 05700 003 53 26 10 2 Tubing 1 4 ID x 100 Long Red 05700 003 03 45 11 2 Tubing 1 4 ID x 100 Long Clear 05700 003 20 67 12 2...

Page 54: ...Connect red wire from gray cable to blue wire from switch Remove locknut on plumbing support brkt and mount switch box over existing stud Re install brkt and route red and white tubes behind blue hose as shown Route gray cable down back and under tub along inlet plumbing remove wires from existing pressure switches and connect to gray cable per note below Back of machine showing use of existing mo...

Page 55: ...49 SECTION 6 ELECTRICAL SCHEMATICS ...

Page 56: ...Avenger Series Technical Manual 7610 003 34 01 Issued 10 07 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS Avenger HT 208 230 VOLT 60 HERTZ SINGLE PHASE 50 ...

Page 57: ...Avenger Series Technical Manual 7610 003 34 01 Issued 05 02 2007 Revised 10 07 2007 SECTION 6 ELECTRICAL SCHEMATICS Avenger HT 480 VOLT 60 HERTZ THREE PHASE 51 ...

Page 58: ...Avenger Series Technical Manual 7610 003 34 01 Issued 05 02 2007 Revised 10 07 2007 SECTION 6 ELECTRICAL SCHEMATICS 52 Avenger LT 115 VOLT 60 HERTZ SINGLE PHASE ...

Page 59: ...SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS 53 ...

Page 60: ...414 FAX 650 635 1919 pndappl aol com P D APPLIANCE 4220 C ROSEVILLE ROAD NORTH HIGHLANDS CA 95660 916 974 2772 800 824 7219 FAX 916 974 2774 COMMERCIAL APPLIANCE SERVICE INC 281 LATHROP WAY 100 SACRAMENTO CA 95815 916 567 0203 800 464 2222 916 567 0324 FAX COLORADO GCS SERVICE INC SHERIDAN CO 303 371 9054 800 972 5314 FAX 303 371 4754 HAWKINS COMMERCIAL APPLIANCE SERVICE 3000 S WYANDOT ST ENGLEWOO...

Page 61: ...NAPOLIS IN 317 545 9655 800 727 8710 FAX 317 549 6286 B622 LA PAS TRAIL INDIANAPOLIS IN 46268 317 290 8060 800 410 9794 317 290 8085 FAX IOWA GOODWIN TUCKER GROUP 2900 DELAWARE AVENUE DES MOINES IA 50317 515 262 9308 800 372 6066 FAX 515 262 2936 parts goodwintucker com CONES REPAIR SVC 1056 27TH AVENUE SW CEDAR RAPIDS IA 52404 319 365 3325 800 747 3326 FAX 319 365 0885 KANSAS GCS SERVICE INC KANS...

Page 62: ...0 284 4427 FAX 314 638 0135 KAEMMERLIN PARTS SVC 2728 LOCUST STREET ST LOUIS MO 63103 314 535 2222 FAX 314 535 6205 petek kps stl com GENERAL PARTS INC 1101 EAST 13TH STREET KANSAS CITY MO 64106 816 421 5400 800 279 9967 816 421 1270 FAX MONTANA RESTAURANT APPLIANCE SVC 7219 ROOSEVELT WAY NE SEATTLE WA 98115 206 524 8200 800 433 9390 FAX 206 525 2890 info restappl com NEBRASKA GOODWIN TUCKER GROUP...

Page 63: ...RGO ND 58103 701 235 4161 800 279 9987 701 235 0539 FAX OHIO CERTIFIED SERVICE CENTER 890 REDNA TERRACE CINCINNATI OH 45215 513 772 6600 800 543 2060 FAX 513 612 6600 sbarasch certifiedsc com CERTIFIED SERVICE CENTER 171J K NORTH HAMILTON RD COLUMBUS OH 43213 614 751 3769 866 862 1252 FAX 614 751 5792 jadkins certifiedsc com CERTIFIED SERVICE CENTER 6025 N DIXIE DRIVE DAYTON OH 45414 937 898 4040 ...

Page 64: ... 800 442 5026 FAX 972 484 2531 GCS SERVICE INC HOUSTON TX 713 785 9187 800 868 6957 FAX 713 785 3979 GCS STOVE PARTS 2120 SOLANA STREET FORT WORTH TX 76117 817 831 0381 800 433 1804 FAX 817 834 7754 bud stoveparts com UTAH LA MONICA S RESTAURANT EQMT SVC 6182 SOUTH STRATLER AVENUE MURRAY UT 84107 801 263 3221 800 527 2561 FAX 801 263 3229 lamonica81 aol com VERMONT NORTHERN PARTS SVC 4874 S CATHER...

Page 65: ...532 FAX 303 778 0268 metroappls aol com INTERNATIONAL GLOBAL PARTS AND SUPPLY 7758 NW 72ND ST MIAMI FL 33166 305 885 6353 H D SHELDON AND CO 19 UNION SQUARE WEST NEW YORK NY 10003 212 627 1759 212 924 6920 CANADA THE GARLAND GROUP 1177 KAMATO ROAD MISSISSAUGA ONTARIO L4W 1X4 905 206 8380 SALES 905 624 1419 FAX 905 624 1851 SERVICE 800 427 6668 FAX 800 361 7745 Avenger Series Technical Manual 7610 ...