Operation Instruction
–technical parameter
1
、
In standby mode, the long press P key enters the parameter mode
;
2
、
presse and to change parameter
3
、
The parameter interface flickers when the parameter value is
modified.At this time, press the P key, save the modified parameter, and
then briefly press the P key to exit the parameter interface and return
the standby page.
Param
ete
r
num
ber
Paramete
r range
Factor
y
settin
g
Description
P 0 1
200~5000
4000
the maximum speed of free sewing
P 0 3
0/1
1
Needle stop position selection (0:up; 1: down)
P 0 4
200~3000
1800
Start back tacking speed
P 0 5
200~3000
1800
End back tacking speed
P 0 6
200~3000
1800
Continuous back sewing speed (W sewing)
P 0 9
0/1
0
Soft start switch (0:off; 1: on)
P 1 5
0/1/2
0
Mode of adding stitch
0: continuous
;
1:half stitch
;
2:one stitch
P 1 6
0~9999
30
Adjust the lift foot response time after the sensor has
detected the cloth.