background image

JA-84P wireless motion detector with built-in camera 

2 / 2 

MHP56106

 

 

5 minute / 1 minute sleep time 

To  save  battery  energy,  the  detector  switches  to  battery-saving  mode  15 

minutes  after  its  cover  is  closed.  The  detector  still  watches  for  movement 
during battery-saving mode.  

The  first  movement  detected  is  instantly  transmitted  to  the  control  panel, 

and 

for the next 5 minutes the detector ignores 

any further 

movement

After  these  5  minutes,  the  detector  then  returns  to  watching  out  for 

movement  until  it  is  re-triggered.  The  sleep  time  can  be  shortened  to  1 
minute by pressing the tamper switch during battery installation. Not pressing 
the tamper switch gives a sleep time of 5 minutes. 

 

Camera testing 

Switch  the  control  panel  to  SERVICE  mode  and  have  an  RC-80  key-fob 

ready. 

1.  Open and close the detector’s cover again. Its

 green indicator will turn 

on 

for 10 sec (enrollment mode to enroll the key-fob as a remote trigger 

for testing the camera)  

2.  Enroll  the  key-fob  by  pressing  any  key  (a  green  LED  flash  confirms 

enrollment)   

3.  Use  the  key-fob  to  take  photos: 

  =  snap  without  flash

  = 

snap 

with flash   

 

4.  Camera test mode lasts for 15 minutes then the key-fob is automatically 

erased from the detector. If you want another 15 minutes testing, repeat 
the  above  procedure  starting  from  1.  Test  mode  can  be  finished 
immediately by pressing 

 and 

 simultaneously. 

After  it  has  been  taken  the 

photo  is  transmitted 

to  the  control  panel  - 

indicated by 

green LED flashing

. Successful transmission is confirmed by a 

long  green flash (2 sec). Unsuccessful transmission is indicated by a series 
of rapid green flashes at the end. The transmission is also indicated on the 
JA-80Q data module (same logic).    

After the photo is received by the control panel, the data module transfers it 

to the server (via the communicator). This transfer is indicated by a red LED 
flashing  on  the  JA-80Q  module.  Successful  transfer  is  confirmed  by  a  long 
red flash (2 sec). Unsuccessful transfer is indicated by a series of rapid red 
flashes at the end. 

The total average time to transfer the photo from the camera to the server 

is about 20 sec. In the case of radio signal interference the transfer can be 
longer  (damaged  data  are  repeated).  Each  photo  also  contains  a  date  and 
time stamp. 

If  the  photo  transfer  was  not  successful,  the  photo  will  only  stay  in  the 

detector’s internal memory.  

 

Normal camera operation  

15  minutes  after  closing  the  cover,  the  detector  changes  from  test  mode  to 

normal operational mode (the test key-fob is erased and the red LED turns off). 

If the control panel is unset (disarmed), 

the detector ignores movements 

and takes no photos. 

During  the  exit  delay 

the  detector  reports  movements  but  takes  no 

photos. 

During  the  entrance  delay 

the  detector  –  when  triggered  –  not  only 

reports a movement but also instantly takes one photo without a flash. The 
photo is then stored in memory. For the next 5 seconds from the moment of 
taking  the  photo  shot,  the  detector  goes  to  sleep  mode.  After  that  the 
detector  returns  to  watching  out  for  movement.  Any  further  detection  of 
movement is reported and responded to according to whether the system is 
in an entrance delay state and/or alarm condition. If an entrance delay is still 
occurring,  the  detector  will  not  take  or  store  pictures  any  more.  If  an  alarm 
state  is  indicated,  the  detector  will  take  photos  the  same  way  as  if  a 
movement  had  been  detected  in  an  instant  loop  (see  below).  If  an  alarm 
triggered  due  to  an  entrance  delay  has  expired  (so  that  no  other  detectors 
have been triggered), then the memorized photo taken during first movement 
detection is transmitted. 

Instant-loop  movement  detection 

is  reported  to the control  panel  and  a 

series  of 4 photos  is taken by the camera. The first photo is taken instantly 
without  a  flash.  The  following  3  pictures  are  taken  at  one  second  intervals, 
each  with  a flash.  After  that any movement  in  the  detection area  is  ignored 
and the pictures are transferred to the control panel. The detector’s inactivity 
period ends 5 seconds after finishing picture transmission. 

 

Alarm verification and flash functions  

The  main  task  of  the  built-in  camera  is  to  verify  real  alarms  caused  by 

human body movement (to recognize false alarms). 

The  detector’s  built  in  flash  illuminates  the  scene,  but  it  also  has  another 

important functions patented by Jablotron: 

a) 

An unexpected flash attracts the intruder to look 

at the detector and 

this   significantly  increases  the  probability  that  the  next  shot    will  show  

the 

intruder’s face 

 

b)  A  flash  also  clearly 

indicates,  to  the  intruder  that  he  was  detected

possibly  making  him  run  away.  If  not  and  (s)he  tries  to  damage  the 
detector,  a  tamper  alarm  is  triggered.  The  tamper  alarm  will  verify  the 
intruder’s  presence even faster than photo transmission does. 

 

Stand alone mode 

In this mode the photos will only be stored locally in the detector’s internal 

memory (last 61 shots). This mode starts automatically when the detector is 
not enrolled to any control panel after inserting batteries. 

After the end of the walk test period (15 minutes) every movement in front of 

the  detector  will  trigger  taking  three  photos  and  storing  them  in  the  internal 
memory. Then the 5 / 1 minute sleep period starts. The flash can be enabled / 
disabled using the DIP switch. The transmit function is disabled automatically. 

Note: No date and time stamps are applied to the photos when the device 

operates in stand-alone mode. 

 

Viewing photos from the detector’s internal memory 

The  detector stores the  last  61  photos  in its  internal memory.  The  photos 

can be viewed by a PC:  

1.  Switch the control panel to SERVICE mode 
2.  Open the detector and disconnect the camera module’s cable 
3.  Take  the cover  with  the camera  to the  PC and  use the cable  (provided 

with the JA-80Q data module) to connect it to the PC USB port 

4.  The camera module is accessible as a removable mass storage device. 

Photos  are  stored  in  BMP  files.  Use  a  suitable  viewer  (i.e.  “Windows 
photo and fax viewer”) to view the photos.  

5.  After viewing the photos reinstall the camera module in the detector and 

switch the control panel to normal operational mode. 

 

Battery replacement 

The  detector  monitors  the  voltage  of  its  batteries  and  if  too  low,  a  report  is 

sent to the control panel to inform the installer or user. The detector continues 
to  function  and  shows  each  detected  movement  with  a  flash  of  its  red  LED. 
Battery  replacement  should  not  be  delayed  by  more  than  two  weeks.  This 
should be done by a qualified technician with the control panel in Service mode. 

After battery replacement, the detector needs about 100 sec to stabilise during 

which its red LED lights continuously. After the LED has stopped indicating, test 
that the detector is functioning (it will be in test mode for 15 minutes).  

Always use new  batteries and replace both of them.  Be careful not to mix 

used and new batteries (even a nearly discharged lithium battery has 3V so it 
is not simple to recognize a discharged battery). 

Expired  batteries  should  not  be  thrown  into  the  garbage,  but  disposed  of 

according to local regulations. 

 

Removing the detector from the system 

If a detector is removed, the control panel reports its removal. The detector 

has to be deleted from the control panel before intentional removal.

   

 

Technical parameters 

Voltage: 

2x Lithium battery type CR123 (3.0V / 2,4Ah) 

Please note: Batteries are not included 
Typical battery lifetime:  

approx. 2 years (one alarm / month, DEL reaction) 

Communication band: 

  868 MHz, Oasis protocol 

Communication range: 

max. 300m (open area) 

Recommended installation height: 

2.0 to 2.5 m above floor level 

Installation height acc. Incert T014A. 

2.0 to 2.4 m above floor level 

PIR detection angle/detection range: 

50° / 12 m (basic lens) 

Resolution of the camera 

160 x 128 pixels, B&W 

Internal memory photo format 

bit map (BMP) 

Format of the photos transmitted to server 

JPG 

Horizontal camera capture angle 

50° 

Range of the flash 

max. 3 meters 

Typical photo transmission time to the control panel 

25 sec 

Typical photo transfer time from the system to server 

15s/GPRS  (JA-80Y) 

 

 2s /LAN  (JA-80V) 

EN 50131-1,EN 50131-2-2, EN 50131-5-3 classification: 

grade  2 

Operational environment according to EN 50131-1  

II. indoor general 

Operational temperature range 

-10 to +40 °C 

Dimensions 

110 x 60 x 55 mm 

Complies with ETSI EN 300220, EN 55022, EN 50130-4, EN 60950-1 
Can be operated according to  

ERC REC 70-03 

FCC ID: VL6JA84P  
INCERT no.: B-903-0001

 

 
 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-84P is in 
a  compliance  with  the  relevant  Union  harmonisation  legislation: 
Directives 

No: 

2014/53/EU, 

2014/35/EU, 

2014/30/EU, 

2011/65/EU.  The  original  of  the  conformity  assessment  can  be 
found at www.jablotron.com - Section Downloads. 

 

Note

:  Although  this  product  does  not 

contain  any  harmful  materials  we 
suggest  you  return the  product  to  the 
dealer  or  directly  to  the  manufacturer 
after use. 

 
 

 

 

Reviews: