User instructions of JA-60 "Comfort"
- 4 -
MDY51410
5.2. Voice message recording (
sequence:
8 0)
Press shortly key
8
then press key
0
and hold it pressed while talking into the control panel’s front grid (max. 20 seconds). After
releasing the 0 key, the message will play back. The message is stored in non-volatile memory and can be changed when ever you
want to by repeating the above steps. Make the message clear and brief. The dialer repeats the message to each called number for 40
seconds.
It is possible to
split the voice message into two different messages
(10 seconds each). Depending on the setting in programing
mode, a particular message will be sent under different situations.
If you want
to record two messages
: press shortly key
8
and then press key
1
and hold it pressed while recording the first message.
To record the second message press shortly key
8
then press key
2
and hold it pressed while talking into the control panel’s front grid.
5.3. Telephone dialer testing (
sequence:
8 9)
Enter
89
and the dialer will call the programmed numbers once. You will hear the telephone line signals from the control panel built in
speaker during the test (if the dialer is triggered by an alarm in normal operation, it will call silently). Testing can be terminated with the
N
key.
If two different voice messages were recorded, then use sequence 88 to test the sending of the first message and 89 to test the
sending of the second message.
Note: if you enter 89 in the user mode when there is an incoming call on the telephone line, the dialer will answer the call. This is the
way to allow the installer to dial in to your system from his computer, even if the dialer was programmed to the "never answer" mode
during installation. But even with this manual approval the installer must know the digital dialer access code (8 digits) to be able to
establish connection. This access code must be programmed during the installation (factory default setting is 00000000).
6. Real time and date setting (
sequence:
4 hh mm dd MM YY)
The control panel has a built in real time clock. All events are stored to the event memory including the time of the event. The clock can
be set by entering:
4 hh mm dd MM YY
hh
-> hours (24 hr. cycle)
mm
->
minutes
dd
-> day
MM
-> month
YY
-> year
Example: on Jun. 30 2005 at 17:15 enter: 4 17 15 30 06 05
7. Battery replacement
All the battery powered items perform regular battery testing. If the life time of the battery is near the end, the system will indicate the
need for battery replacement (low battery indicator and address of the particular item will be shown on the LED display).
When any detector or keypad asks for new batteries, do following:
•
switch the control panel to the user mode (F0 master code)
•
open the cover of the detector (keypad) and replace its batteries with new ones (use only corresponding size and good quality
alkaline batteries). Wait for apr. 20 sec before inserting batteries
•
close the device’s cover and test the device to confirm it is working.
•
to exit User mode, press the N key on the control panel.
Recommendations:
•
the system should be annually inspected (function testing, condition of back up batteries, working range of the items etc.) by a
professional. After 5 years, the control panel and the outdoor siren back up batteries should be replaced with new ones