User instructions of JA-60 "Comfort"
- 2 -
MDY51410
Optional user functions
(following functions can be enabled or disabled in the programming mode):
F 1
arming without a code
- disarming is only possible with an access code (entry of F1 can be used on JA-60D keypad for this
function). If the system is
split
, then this code can be used for arming of
section A
.
F 2
partial (home) arming
- detectors addressed to B section will be ignored (except Smoke & Gas detectors). On the JA-60D
keypad code F2 can be used for partial arming. If the system is
split
, then this code can be used for arming of
section B
. If the
control panel was not programmed for partial arming or was not split, this code has no function.
F 3
door opening
- will release electric door lock if connected to the system (PgX or PgY outputs). On the JA-60D keypad, code F3
can be used for this function.
F 7
panic alarm
- if you are under duress, press this button before your code, this will trigger a silent alarm; if the system is armed, it
will also disarm. On the JA-60D keypad, code F7 can be used before your code to trigger a panic alarm.
F 4
memory reading
- indicators and LED display will show where and what happened, press key 4 multiple times to go deeper into
the memory. Complete events list including date & time can be viewed using PC with Comlink SW.
F 5
new Master Code
- after F 5 the current master code must be entered followed by the new one twice.
Example: to change Master code from 1234 to 2738 enter: F5 1234 2738 2738
F 6
new User Code
- after F 6 the valid master code must be entered, number of the new user code (01 to 14) and then the new
user code.
To erase any User code
completely, set it to 0000
Example: user code number 5 can be entered for combination 6789 while Master code is 2738 entering: F 6 2738 05 6789.
F 9
voice message listening
- to check the message(s) of the telephone dialer (control panel built in speaker will play all the
recorded messages once).
F 0
user
(programming)
mode
- entering
F 0 Master Code
will be confirmed by „U“ on the LED display. The control panel is now in
the user mode for bypass setting, system testing, battery replacement, voice dialer programming (if enabled by installer).
Entering F 0 Service Code is used by the installer to enter the programming mode.
N
exit
- not completed function code, memory reading, user mode etc.
Note: While in the programming mode, you can select that functions
F1
,
F2
,
F3
,
F4
and
F9
can be used only when followed by a code
(Master or User). Acoustic indications and other features of the system can also be customized in the programming mode. Wireless
keypad JA-60D can have its own master code and one user code. Both JA-60D codes can be different than the control panel codes.
4. Zone bypassing
By using the master code, wireless detectors can be bypassed within a selected area of the house. Bypass setting:
•
open
User mode
entering
F 0 Master Code
- will be confirmed by „U“ on the LED display
•
press
1
to enter the bypass menu
•
keys
1 and 6 scroll
enrolled wireless detectors.
•
select the detector to be bypassed
•
press key
2
and hold it for two seconds to set
one arming period bypass
of the selected detector (battery indicator will start
flashing to confirm the bypass). If you press 2 again, this bypass will be switched off etc. (on - off - on,...).
•
similar way with key
3 for a permanent bypass
of the zone (confirmed with continuous lighting of the battery indicator). If
you press 3 again, this bypass will be switched off etc. (on - off - on,...).
•
repeating the above steps you can set up and check requested bypasses
•
to
cancel all
selected
bypasses
press and hold key
4
while in the bypass menu
•
to
exit
the bypass menu pres
N
, to exit user mode press N again
Arming of the system while a zone is bypassed
is confirmed with four beeps and "
b
" will be indicated on the display during the exit
delay period.
Notes:
•
Be sure to cancel a permanent bypass after there is no need for the bypass
•
If one arming period bypass was selected for a zone, this bypass is automatically canceled after the system is armed and then disarmed. This
remains valid for arming and disarming even if the system is split into two sections.
•
All bypasses will be canceled after programming, factory default reset or after the main board’s power is disconnected
•
The bypass menu is only available in the user mode