Figure 3-4 Mirror Configuration Screen
Configuration object and description is:
Note
: You cannot set fast speed port(s) mirror to a low-speed port. For example, there is
problem if you try to mirror 100Mbps port(s) to a 10 Mbps port. So, destination port should
have equal or higher speed comparing to source port. Besides, source port and destination
port should not be same one
3.4 Thermal Protection Configuration
Thermal protection is for detecting and protecting working switch. When switch detected
port temperature is higher that defined temperature, system will disable the port, to protect
switch itself.
After clicking "
Port Configure
" > "
Thermal
Protection
", following screen will appear as: