14
BLK
ALL COMPRESSORS
(GREEN)
R
POWER ON
18 GA WHITE
THOMAS (BROWN)
GAST (BLACK)
DEVILBISS (BLACK)
18 GA BLACK
18 GA BLUE
18 GA BLUE
12 GA BLACK
18GA BLACK
FACTORY WIRING
FIELD WIRING
120 VAC
(NEUT)
OPTIONAL CYCLE COUNTER
120VAC, PART # 8641
OPTIONAL COIN COUNTER
120VAC, PART # 8641-1
!! IMPORTANT !!
*20AMP SERVICE IS
REQUIRED
FOR DEVILBISS UNITS*
18GA BLACK
!! IMPORTANT !!
*10AMP SERVICE IS
REQUIRED FOR TWIN
THOMAS & GAST UNITS*
THOMAS (BLUE)
GAST (WHITE)
DEVILBISS (WHITE)
TO
COMPRESSOR
TO
COMPRESSOR
120 VAC
(HOT)
120 VAC (GROU
ND)
8124B001
8712SS5
8673-9
5914
B
C
A
D
G
F
H
E
WATER SOLENOID
BLACK
BLACK
TO NO
TO B
ONLY USED WITH UNITS
WITH WATER FEATURE
8
697
8726
SWITCH CONNECTIONS ARE THE BLUE WIRES CURRENTLY
SHOWN GOING TO THE COIN ACCEPTOR. WHEN SWITCH IS
USED COIN ACCEPTOR IS NOT USED.