Maintenance and lubrication
Please ensure that load hooks and/or load eye mounts
are regularly checked, at least once a year.
Especially
important:
in areas where wear-promoting conditions
such as high ambient temperatures or corrosive
substances in the atmosphere are present, or where
lubricants may be washed out,
the frequency of
maintenance and inspection intervals must always
be increased.
H A Z A R D S I N T H E C A S E O F I N S U F F I C I E N T
M A I N T E N A N C E / L U B R I C AT I O N
DA N G E R !
In the event of insufficient mainte-
nance/lubrication the extent of wear may
be so high that there is a danger of loads
falling.
P R E V E N T I O N O F DA N G E R S
Dangers are avoided by regular maintenance/lubrication
in suitable intervals.
When the axial play of the installed hook or load
eye exceeds the maximum play specified, the worn
parts must be replaced.
Bottom block with load hook or load eye
Load sleeve with load hook or load eye
C H E C K I N G A X I A L P L AY
powered by air !
M A I N T E N A NC E
Page 57
max. 2.5 mm
max. 2.5 mm
Summary of Contents for Profi 025Ti
Page 1: ...powered by air J D N O P E R A T I O N M A N U A L A I R H O I S T S...
Page 65: ...powered by air NOTES Page 65...
Page 66: ...powered by air NOTES Page 66...
Page 67: ...powered by air NOTES Page 67...
Page 217: ......