WARNING 

Before installing, please take a few minutes to read this handbook. Keep it in a sure place 
and  easily  reachable  for  future  references.  If  this  appliance  is  not  properly  installed,  it 
could  cause  fire  damages  to  the  property,  injuries  and  death.  To  reduce  fire  hazards, 
follow instructions contained in this handbook. 
 
Contact  an  official  inspector  (ex:  a  fireman)  or  your  insurance  company  for  installation 
permit. Always respect the provincial and municipal building codes of your region. 

 

Do not connect this appliance to a chimney that already serves for another wood stove. 

 

The  existing  chimney  should  be  inspected  before  any  installation.  In  doubt,  consult  a 
specialist. 

 

Never use a non-isolated exterior conduct or a single pipe as an exterior exit. 
 
Minimum clearances found in this manual must be observed. 

 

Install all firebricks before lighting the stove (if it is not already done). 

 

Never use a non-isolated exterior duct or a pipe to evacuate chimney smoke. 

 

Do not install in a mobile house. 

 

Keep  all  combustible  material  (clothing,  furniture,  wood,  matches,  plastic,  etc)  at  a 
distance of at least 91.5 cm (3 feet) from the appliance. 

 

Do not use chemicals or fluids to light the fire. Waste and other flammable materials such 
as gasoline, naphtha or engine oil should not be burnt in your stove. 

 

This appliance is approved to burn wood. Do not use any other combustible. 

 

Wood  should  not  be  stocked  within  the  recommended  minimums  clearances  or  in  the 
necessary space for the loading and the ashes evacuation. 

 

Do  not  burn  wet  or  freshly  cut  wood.  Do  not  use  construction  debris  such  as  pieces  of 
2x4 or plywood. 

 

Summary of Contents for ULTIMATE

Page 1: ...Argon Qu bec Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com OWNER S MANUAL ULTIMATE WOOD STOVE Revised October 22 2012 ULTIMATE Certified and tested according to UL 1482 00 and ULC...

Page 2: ...G 13 FANS AND THERMODISC 14 PREVENTIVE MEASURES AND MAINTENANCE 15 REPLACEMENT PART L IST 16 INSTALLATION OF THE FIREBRICKS 17 Figure 1 0 18 LIMITED LIFE WARRANTY 20 READ CAREFULLY THIS MANUAL AND KEE...

Page 3: ...xterior conduct or a single pipe as an exterior exit Minimum clearances found in this manual must be observed Install all firebricks before lighting the stove if it is not already done Never use a non...

Page 4: ...of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible material adjacent...

Page 5: ...d the doors in order to ensure good ventilation This special paint is conceived to tolerate temperatures until 1200 F 650 C CREOSOTE The wood burning slowly produces tar and other organic steams which...

Page 6: ...t 33 5 in 85 1 cm Exterior width 27 5 in 70 0 cm Exterior depth 37 in 94 cm Door openning 16 X 10 5 in 41 0 X 27 0 cm Interior height 13 5 in 34 3 cm Interior width 20 5 in 52 1 cm Interior depth 25 2...

Page 7: ...oval of the authorities responsible for the application of the building code 4 Install the chimney and an insulated wall thimble for an installation passing through a wall according to the instruction...

Page 8: ...CAN CSA B365 ULC S635 ULC S640 UL 1777 norms For the chimney follow the chimney manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The Ultimate must be installed in accordance with the applic...

Page 9: ...LATION ON A CATHEDRAL ROOF The Ultimate must be installed in accordance with the applicable local laws or the CAN CSA B365 ULC S635 ULC S640 UL 1777 norms For the chimney follow the chimney manufactur...

Page 10: ...B365 ULC S635 ULC S640 UL 1777 norms For the chimney follow the chimney manufacturer s instructions VERTICAL INSTALLATION The Ultimate must be installed in accordance with the applicable local laws or...

Page 11: ...fectly your decoration by its originality and its heat With the addition of A heat shield it requires only 10 inches of clearance to the back and 20 inches of the sidewalls when the installation is ma...

Page 12: ...wood stove should be placed on a non combustible plate under the appliance which must exceed 18 inches to the front 8 inches on each side and 8 inches to the back Only use non combustible materials Ex...

Page 13: ...by twisting together a few sheets of newspaper in a torch Light up the paper torch and hold it as close as possible to the pipe inside the chamber to warm up the chimney 2 Place papers and kindling in...

Page 14: ...ction the heat reaching a temperature of 120o F activates the thermo disc At this moment the thermo disc activates the fans for a better distribution of heat in your home As soon as the heat goes unde...

Page 15: ...5 Do not alter or modify the air intakes of the appliance in order to get a stronger fire 6 To clean the glasses J A Roby Inc recommends using products sold for this purpose or an oven cleaner Avoid...

Page 16: ...16 REPLACEMENT PART L IST BRICKS WOOL PLATES USED TO RETAIN WOOL PIPES GLASS BRICKS SUPPORTS DOOR HANDLE FANS CORDS TO ORDER PARTS PLEASE CONTACT YOUR AUTHORIZED RETAILER...

Page 17: ...lled you can then tighten the screws 4 Third install C 12 B 2 A 2 E 2 bricks on the side wall 5 To install the last top bricks the rock wool and the retaining plate follow the last step before lightin...

Page 18: ...18 Figure 1 0...

Page 19: ...19...

Page 20: ...nsportation charges The 2nd year J A ROBY Inc assume 50 of repairs according to the above conditions The 3rd year J A ROBY Inc assume 45 of repairs according to the above conditions The 4th year J A R...

Reviews: