Chimney connector installation. 

 

The chimney connector is a set of single wall or double wall flue 
pipes  and  elbow  installed  between  the  stove  collar  and  the 
chimney collar. The  single  wall chimney connector  is  sold into 
any  hardware  store  and  are  not  homologated  and  certified. 
Some rules must be followed to install it and can be found in the 
installation codes for wood heater.  

 

Double wall chimney connector. 
The  stove  was  design  and  tested  with  a  single  wall 
chimney connector with heat shield
 but it is possible to 
install  a  6  inches  (15.2  cm)  double  wall  certified  chimney 
connector  

ATTENTION: 

 

For the clearance between combustible materials 
and  double  wall  chimney  connector,  see 
manufacturer manual. 

 

 

Single wall chimney connector.. 

For  the  single  wall  chimney  connector  you  must  use  The 
single wall or double wall chimney connector and it must be 
6  inches  diameter  and  have  a  minimum  thickness  of  24 
gauge (0.025 inches 0.64 mm) For the single wall section 
and  elbow.  Install  a  metal  heat  shield,  1  inches  (25.4 
mm) offset.
  

 

ATTENTION:  

 

If heat shield is not present you must move away 
the stove to keep 18 inches (45.7 cm)  clearance 
between combustibles materials and the chimney 
connector. 

 

Any  horizontal  section  must  have  a  1/4  inches 
(6.35  mm)  by  feet  (30  cm)  slope  toward  the 
chimney collar. 

 

Clearance between roof and horizontal single wall 
chimney connector must be 18 inch (45.7 cm) or 
more. 

 

Clearance  between  roof  and  horizontal  double 
wall chimney connector, follow chimney connector 
manufacturer indication  

 
ALL SECTION AND ELBOW MUST BE CLEAN AND 
IN  GOOD  CONDITION  AND  MUST  BE  APROVED 
FOR A CORDWOOD FUEL. 

 
 

1.  Chimney connector assembly installation. 
Make  a  summary  installation  of  all  sections  and  elbows  (if 
necessary)  to  ensure  that  you  meet  the  clearances  and 
inclinations of the horizontal sections and check that you have 
all the necessary parts to final installation. 

o

 

For direct vertical installation you will need.  

 

1 adequate length for vertical section  

 

1  x  adequate  length  of  telescopic  chimney 
connector  section  allowing  you  to  connect 
the  last  chimney  connector  section  to  the 
roof support collar. 

Note: Additional section can be used for higher roof. 

 

o

 

For horizontal run installation you will need 

 

1 adequate length of vertical section 

 

1 x 90° elbow or 2 x 45°elbow. 

 

1  x  adequate  length  of  telescopic  chimney 
connector section 

 

Note: For better performance two 45 degree elbow, with or 
without straight section between are preferable. 

2.  Disassemble the whole thing and start screwing the pieces 

from the stove to the roof chimney collar  

3.  Insert entirely the roll formed end into the stove collar and 

screwing 

it 

with 

minimum 

of 

screws.

 

WARNING:  It  is  mandatory  to  screw  the  pipe  to  the 
stove collar and also at each joints with a minimum of 
3 screws. 

4.  Install  all  the  next  section  up  to  the  roof  chimney 

support and screw every chimney connector parts with 
3 screws 

WARNING: It’s mandatory to screw all joint with a 
minimum of 3 screw. 
 

5.  Install all the next section and screw it to the last 
6.  Screw the last section to the ceiling chimney collar. 

DO NOT CONNECT CONECT THIS UNIT TO A CHIMNEY 
FLUE SERVING ANOTHER APPLIANCE.. 

CONNECTOR PIPES SHOULD NEVER PASS THROUGH 
THE CEILING, THROUGH A WALL, IN A CLOSET, IN AN 
ATTIC  OR  OTHER  ENCLOSED  AREA  THAT  COULD 
CAUSE  HEAT  BUILDUP.  IF  YOU  NEED  TO  PASS 
THROUGH  COMBUSTIBLE  MATERIAL,  MAKE  SURE 
THAT  YOUR  INSTALLATION  COMPLIES  WITH  CAN  / 
CSA-B365. 

.

Summary of Contents for ultimate 2015

Page 1: ...ULTIMATE 2015 CAN ULC S627 00 UL 1482 2011 CAN CSA STD B415 1 10 Instruction Manual 490 rue de l Argon Qu bec CANADA G2N 2C9 T l 418 849 8095 Fax 418 849 0077...

Page 2: ...ource 18 Exterior Air Intake pipe 18 Installation of Air Intake Pipe 18 Air Inlet Obstruction 18 Stainless steel deflector replacement 19 Front deflector Add on Replacement 19 Stainless steel tubes In...

Page 3: ...imney with a flue liner with a 6 inches diameter 15 24cm WARNING N B BE WARNED THAT THE LOCAL S CODES AND RULES CAN HAVE MORE SPECIFIC REQUIREMENT THAN THIS MANUAL YOU CAN CONSULT A MASTER INSTALLER F...

Page 4: ...4 2 Nameplate...

Page 5: ...x 9 5 inches 40 6 cm x 25 4 cm Interior Height 15 inches 38 cm 15 inches 38 cm Interior Width 20 inches 50 8 cm 20 inches 50 8 cm Interior Depth 25 inches 64 cm 25 inches 64 cm Maximum log length 24 i...

Page 6: ...ollowing dimensions are the minimums values and it can be higher Canada 44 113 73 cm 53 136 53 cm 3 8 in thickness 1 cm USA 44 113 73 cm 51 131 44 cm 3 8 in thickness 1 cm It s necessary to protect th...

Page 7: ...nce In the case with a smoke simple pipe without heat shield you must installed the cooker stove that the smoke pipe is to 18 inches of all combustible material therefore the MINIMUM clearance at the...

Page 8: ...stove on the back and be careful to protect the paint 4 Unscrew the nut not completely 5 Install the legs 1 like the illustration and secure it with nut and washer 2 3 Attention Be sure the legs are i...

Page 9: ...front the 4 bricks previously placed 3 Insert 2 brick A each side of the pilot 4 Insert brick A and B to finish under the door Back firebricks installation 1 Put 4 bricks A on the back wall 2 Begin t...

Page 10: ...The firebricks must be put on the 5 pipes from the bottom of combustion chamber Bricks keep a maximum of heat inside the combustion chamber and help the air ratio to burn the most of wood pollution ga...

Page 11: ...ay is not obstructed 4 Put two half metal disk over the rockwool near the rear deflector already in place Be sure to put it under the rear deflector to maximise the clearance between rockwool and the...

Page 12: ...leeve inside 4 Install the chimney following the manufacturer instruction 5 Put the stove directly on the floor aligned vertically with the center of chimney and trace the side of the stove on the flo...

Page 13: ...WOOD FUEL 1 Chimney connector assembly installation Make a summary installation of all sections and elbows if necessary to ensure that you meet the clearances and inclinations of the horizontal sectio...

Page 14: ...he manufacturer s manual of the chimney for a more detailed method for your chimney 1 Determine the total length needed for your chimney 2 Cut the holes into all floor and roof 3 If you need to cut a...

Page 15: ...anner you have to To install the stove onto an abandoned masonry fireplace and use the good condition masonry chimney the chimney must have inside a certified metallic sleeve cover up all the chimney...

Page 16: ...applicable local laws or the CAN CSA B365 NFPA211 USA norms Follow the chimney manufacturer s instructions to install the chimney Always pass chimney between joists If a joist need to be cut referring...

Page 17: ...nstaller Always frame around chimney Keep minimal clearances written into your chimney manual Do not fill the gap between the fire stop and the chimney Nothing must be in contact with the chimney Alwa...

Page 18: ...the structure when a exterior air intake is installed Installation of Air Intake Pipe 1 To install the exterior air intake pipe find the hole under the cook stove back and fold the 3 tabs outside the...

Page 19: ...ol and half round plate Following instruction into the stainless steel tubes replacement section Stainless steel tubes replacement Although the tubes are in stainless steel With extreme temperature an...

Page 20: ...the cotter pin into the last hole at the other side 4 Split the cutter pin to lock it 5 Install the next tube To remove tubes do steps in reverse order Tube support installation Put the support over...

Page 21: ...r down the handle The wood will burn more rapidly when more primary air is set Otherwise the wood burn more slowly and more efficiently with the handle set to secondary air You can balance the primary...

Page 22: ...an still lit If embers have enough oxygen it can still lit some hours and so some few days It s mandatory to store ash pending disposal Into a metal container with an airtight metal lid correctly clos...

Page 23: ...iberglass rope and close and lock the door 4 If the paper easily slide when you pull it do steps 1 to 3 another time 5 If the door side touch the frontage of the stove and the piece of paper slide eas...

Page 24: ...on and cut it inches over the require length 5 Take the fresh cut end of the fiberglass rope and push the fiber inside to make a clean end 6 Add high temperature latex inside the end of fiberglass rop...

Page 25: ...25 9 Appendix 1 Door assembly Square Door...

Page 26: ...26 Arc Door...

Page 27: ...27 10 Appendix 2 Fans electric wiring diagram Therm O disk Box parts description...

Page 28: ...ricks Stove ceramic glass Arc Stove ceramic glass Rectangular Spring Handle Stove Door with handle Fans Flat fiber glass rope around glass Round fiberglass rope Ash Plug Slotted Brick Washer To ordere...

Page 29: ...etion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty...

Reviews: