13
Chimney connector installation.
The chimney connector is a set of single wall or double wall flue
pipes and elbow installed between the stove collar and the
chimney collar. The single wall chimney connector is sold into
any hardware store and are not homologated and certified.
Some rules must be followed to install it and can be found in the
installation codes for wood heater.
•
Double wall chimney connector.
The stove was design and tested with a single wall
chimney connector with heat shield but it is possible to
install a 6 inches (15.2 cm) double wall certified chimney
connector
ATTENTION:
•
For the clearance between combustible materials
and double wall chimney connector, see
manufacturer manual.
•
Single wall chimney connector..
For the single wall chimney connector you must use The
single wall or double wall chimney connector and it must be
6 inches diameter and have a minimum thickness of 24
gauge (0.025 inches 0.64 mm) For the single wall section
and elbow. Install a metal heat shield, 1 inches (25.4
mm) offset.
ATTENTION:
•
If heat shield is not present you must move away
the stove to keep 18 inches (45.7 cm) clearance
between combustibles materials and the chimney
connector.
•
Any horizontal section must have a 1/4 inches
(6.35 mm) by feet (30 cm) slope toward the
chimney collar.
•
Clearance between roof and horizontal single wall
chimney connector must be 18 inch (45.7 cm) or
more.
•
Clearance between roof and horizontal double
wall chimney connector, follow chimney connector
manufacturer indication
ALL SECTION AND ELBOW MUST BE CLEAN AND
IN GOOD CONDITION AND MUST BE APROVED
FOR A CORDWOOD FUEL.
1. Chimney connector assembly installation.
Make a summary installation of all sections and elbows (if
necessary) to ensure that you meet the clearances and
inclinations of the horizontal sections and check that you have
all the necessary parts to final installation.
o
For direct vertical installation you will need.
1 adequate length for vertical section
1 x adequate length of telescopic chimney
connector section allowing you to connect
the last chimney connector section to the
roof support collar.
Note: Additional section can be used for higher roof.
o
For horizontal run installation you will need
1 adequate length of vertical section
1 x 90° elbow or 2 x 45°elbow.
1 x adequate length of telescopic chimney
connector section
Note: For better performance two 45 degree elbow, with or
without straight section between are preferable.
2. Disassemble the whole thing and start screwing the pieces
from the stove to the roof chimney collar
3. Insert entirely the roll formed end into the stove collar and
screwing
it
with
a
minimum
of
3
screws.
WARNING: It is mandatory to screw the pipe to the
stove collar and also at each joints with a minimum of
3 screws.
4. Install all the next section up to the roof chimney
support and screw every chimney connector parts with
3 screws
WARNING: It’s mandatory to screw all joint with a
minimum of 3 screw.
5. Install all the next section and screw it to the last
6. Screw the last section to the ceiling chimney collar.
DO NOT CONNECT CONECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE..
CONNECTOR PIPES SHOULD NEVER PASS THROUGH
THE CEILING, THROUGH A WALL, IN A CLOSET, IN AN
ATTIC OR OTHER ENCLOSED AREA THAT COULD
CAUSE HEAT BUILDUP. IF YOU NEED TO PASS
THROUGH COMBUSTIBLE MATERIAL, MAKE SURE
THAT YOUR INSTALLATION COMPLIES WITH CAN /
CSA-B365.
.