Installation.
Floor protection.
Your stove must be installed on a non-combustible material plate to protect the floor and avoid fire would be caused by:
•
Projections of sparks when door opening or loading logs
•
The heat radiation when stove runaway should have an ignition to the floor and the coating.
•
Flow of creosote when there is a fire chimney
The coating used must be non-combustible and approved according to standard UL1618 for USA or approved to the locals codes
(Example: cement, brick, ceramic tiles…)
Floor protection plate minimum dimensions.
The following dimensions are the minimums values and it can be higher.
Canada:
•
41 7/8 (106 cm)
•
47 5/8 (115.88 cm)
•
3/8 in thickness (1 cm)
Unites States
•
41 7/8 (106.42 cm)
•
45 5/8 (115.88 cm)
•
3/8 in thickness (1 cm)
It’s necessary to protect the floor behind the horizontal
connecting pipe section to the chimney of 2 inches (5cm)
besides connecting pipe and up to the vertical connecting
pipe. You can extend the protection plate while respecting the
clearances of each side of stove.