background image

 

July 13, 2017 

 

 

12 

Mobile home installation 

DANGER DO NOT INSTALL IN BEDROOM. 
WARNING THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME  FLOOR,  WALL,  AND  CEILING/ROOF  MUST  BE 
MAINTAINED. 
VAPOR  BARRIER  EFFICACITY  AROUND  THE  CHIMNEY 
AND  FRESH  AIR  INTAKE  MUST  BE  KEPT  IN  GOOD 
CONDITION.  

1)  Follow the «General stove installation» (p.10) from steps 

1 to 10. 

2)  The following requirements are MANDATORY for 

mobile home installation. 

a.  The stove must be fixed permanently on the mobile 

home’s floor with bolts and nuts.  

b.  The exterior air intake must be installed.  
c.  The stove must be electrically-grounded to the mobile 

home’s chassis. In the USA, electrical grounding with   

8 gauge wire using star washers and certified 
terminals is mandatory. 

d.  All of the following equipment must be certified and 

approved for mobile home installation. 

 Double wall chimney pipe; 

 The chimney system; 

 The roof flashing; 

 The Storm collar; 

 Chimney cap with fire screen; 

 Firewall; 

 Chimney ceiling support; 

 Decorative collar.

 

 

e.  If  the  chimney  is  exposed  outside  from  a  wall  and 

placed lower than 7 feet (213 cm) above the ground 

level  where  the  mobile  home  is  situated,  a  guard 

must be installed around the chimney at the height 

of    7  feet  (213  cm).  If  openings  are  made  in  the 
guard,  they  must  be  less  than  ¾  inch  (19.5 mm) 

wide. guard openings must be kept at least 4 inches 

(10.2 cm) away from the chimney surface in order to 
avoid contact. 

f. 

The chimney must exceed of at least 3 feet (91.4 cm) 

the highest point of the opening made in the roof and 

it must also exceed of 2 feet the highest point of the 
roof inside a 10 feet distance from the chimney. 

g.  Be sure to seal correctly the flashing of the roof, the 

firewall and the exterior air intake with sealant. You 
should also pay attention to the efficacy of the vapor 
barrier is not compromised.  

3)  Always keep the door closed. Open it only when adding 

wood or when starting a fire. 

4)  To close the exterior air intake when the stove is not in 

use, a damper must be installed in the air intake pipe. 

5)  Don’t forget to open the damper when you operate your 

stove so that smoke will not fill the house. 

6)  Always use certified parts for mobile home. Never use a 

substitute for replacement. 

Summary of Contents for Elda

Page 1: ...5 Fax 418 849 0077 www jaroby com Certified and tested according to Canadian Safety ULC S627 00 United States Safety UL 1482 2011 Emission EPA Method 28R ASTM2510 Efficiency CSA B415 1 10 Elda Cuistot...

Page 2: ...17 STAINLESS STEEL TUBES REPLACEMENT 18 Stainless steel tubes Installation 18 How to install the tubes 18 OPERATING INSTRUCTIONS 19 Burning regime control 19 Lightning fire 19 First fire 19 Keeping a...

Page 3: ...ation see pages 19 20 26 28 It is against U S federal regulations to operate this wood stove in an inconsistent manner with the operating instructions in this manual Mobile home approved This applianc...

Page 4: ...cm 12 ft 366 cm Exterior height 37 in 95 25 cm 58 in 148 6 cm 58 in 148 6 cm Exterior width 41 in 105 7 cm 41 in 105 7 cm 51 in 131 4 cm Exterior depth 26 in 66 7 cm 26 in 66 7 cm 26 in 66 7 cm Door...

Page 5: ...The heat radiation from the stove which might cause an auto ignition to the floor or to the floor covering Possible flow of creosote when there is a fire chimney The coating used for the protection mu...

Page 6: ...decor by his originality and warmth Here is the minimum clearance for different certified flue pipes Double wall flue pipe distance Single wall flue pipe with shield Single wall flue pipe To know how...

Page 7: ...warmer 1 as well as the decorative faceplate 2 1 Open the installation opening at the bottom right of the warmer by removing the screws 5 and the plate 4 2 Place and align the warmer with the correspo...

Page 8: ...f the gas from wood which wouldn t be burnt in any other manner The rockwool above the brick prevents leakage between the bricks and keeps a maximum heat inside combustion chamber It must cover up all...

Page 9: ...two half round steel plates over the rockwool near the rear deflector already in place Be sure to put them under the rear deflector to maximise the clearance between the rockwool and the rear deflect...

Page 10: ...ave to be connected to 6 inches 15 24 cm factory build chimney HT UL 103 or CAN ULC S629 compliant or a 6 inches 15 24 cm masonry chimney with a homologated sleeve inside The masonry chimney liner mus...

Page 11: ...indication s for approved double wall chimney pipe ALL PIPE SECTIONS MUST BE CLEAN AND IN GOOD CONDITION AND THEY MUST BE APPROVED FOR CORDWOOD FUEL How to set the pipe sections Make an installation...

Page 12: ...mney is exposed outside from a wall and placed lower than 7 feet 213 cm above the ground level where the mobile home is situated a guard must be installed around the chimney at the height of 7 feet 21...

Page 13: ...ry for your chimney 2 Cut the holes in all the floors and in the roof 3 If you need to cut a joist be sure to strengthen the adjacent joists and frame the hole respecting the minimum dimensions betwee...

Page 14: ...ity to find the latest information in terms of construction standards To install a stove with a chimney serving a masonry fireplace you must have a certified stainless steel sleeve inside covering up...

Page 15: ...accordance with the applicable local laws or the CAN CSA B365 NFPA211 USA norms Regarding the installation of chimney follow the chimney manufacturer s instructions Always pass chimney between joists...

Page 16: ...tified Installer Always frame around chimney Keep minimal clearances as written in your chimney manual Do not fill the space between the frame and the chimney Nothing must be in contact with the chimn...

Page 17: ...T BE FIXED TO THE STRUCTURE WHEN AN EXTERIOR AIR INTAKE IS INSTALLED Installation of Air Intake Pipe You can find external air intake head and grating in hardware store The back panel is removed in th...

Page 18: ...stall The three tubes in the back 1 are perforated from a single side and the second tube in the front 2 is also perforated from a single side but with bigger holes than the other tubes The first tube...

Page 19: ...owing the instructions of the manufacturer you are ready to light it up 1 Pull the handle under the front table of the stove forward to let the air admission enter in the combustion chamber 2 Put pape...

Page 20: ...ommon method used for cordwood Season wood outdoor in summer for at least 6 months before use Properly seasoned wood is darker has cracks at the ends and sounds hollow when one piece is smacked agains...

Page 21: ...ulf in the opening and it will cool down the chimney and diminish the draft inside the stove Moreover smoke might come out from the openings if the draft in the chimney diminishes too much Lids above...

Page 22: ...the chimney when it gets hot enough It is therefore important to respect the minimum chimney length according to the standard to get the optimal performance You can refer to the section of the chimne...

Page 23: ...are 4 access points 1 The 2 round lids on the hob which allow the cleaning of the oven top 2 The little rectangular hatch located on the top right corner of the hob which allows access to the right si...

Page 24: ...ncompletely burned it produces tar and other organic vapors which condensate as creosote The creosote vapor condenses on the relatively cold flue walls As a result creosote residue accumulates on the...

Page 25: ...ith a spanner partially or completely so that you can liberate the upper part of the door 3 Remove the tilted door from the lower hinge by lifting it To reassemble the door 1 Put the door on the botto...

Page 26: ...round the groove without giving any tension and measure the length of the rope 5 Add inch to the length measured in step 4 and repeat the step 2 3 for the new rope end Fiberglass rope installation 1 P...

Page 27: ...July 13 2017 27 APPENDIX 1 Exploded diagram of doors Oven door Glass dimension Order Code CB VPF...

Page 28: ...July 13 2017 28 Square Stove door Glass Dimension Order Code CB VPC...

Page 29: ...July 13 2017 29 Arc Stove door Glass dimension Order Code CB VPA...

Page 30: ...July 13 2017 30 Reservoir Door Glass dimension Order Code CB VPR...

Page 31: ...enir la temp rature de l eau sur une p riode prolong e Attention Pour remplir le r servoir d eau chaude J A Roby pr conise l utilisation d une bouilloire conventionnelle en m tal plac e directement su...

Page 32: ...s 4 espaces du r chaud pr vus cet effet 3 Appuyer le r servoir a eau sur les 4 vis puis serrer les vis compl tement X 4 INSTALLATION DU R SERVOIR 1 Screw partially the 4 screws A provided with the wat...

Page 33: ...et de l eau 4 Replacer le r servoir en le pla ant plut t vers l arri re afin que la porte n heurte pas la t te du robinet en la refermant FILLING OF THE WATER TANK 1 Open the lid and remove the second...

Page 34: ...NDIX 3 Replaceable parts Bricks Door glass Spring Handle Stove Door with handle Flat fiber glass rope around glass Round fiberglass rope Ash Plug Slotted Brick Washer Call your stove seller representa...

Page 35: ...ranty repair are not covered The manufacturer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion...

Reviews: