14
FANS AND THERMODISC
The 115 volts fans must be screwed under the ventilation conduct at the planned place in
the appliance rear. The protection thermodisc box must be fixed at 72 inches (182,88cm)
from the appliance on the ventilation conduct. A hole must be done in order to permit the
air coming from the fans to touch lightly the thermodisc. Plug the terminal.
When the appliance is in function, the heat reaching a temperature of 120oC activates the
thermodisc. At this moment, the thermodisc activates the fans for a better distribution of
heat in your home. As soon as the heat goes under 120oC, the thermodisc automatically
stops the fans.
When the appliance is in fonction, and that the protection thermodisc fixed on the
ventilation conduct reaches a temperature of 160
0
F, the thermodisc will stop the fans and
will close the air entry in order to slow down the combustion and will stop distributing
the heat in the ventilation conduct of your home. When the heat goes under 160
0
F, the
thermodisc will automatically allow the air entry openning and will start the fans.
If you use the appliance without thermostat, see the section named “ In case of extended
electric failure”
The electrical cord of the fans must never touch the appliance surfaces in order to
avoid electrical shock or fire.
ELECTRICAL PLAN