background image

FORM NO. G11-464 REV. 7

Supersedes Form No. G11-464 Rev. 6

GAS FURNACES

Annual Fuel Utilization Efficiency - 

AFUE

THIS MODEL

ENER      UIDE

97%

78%

HIGH

MID

82%

88%

92.0%

RGTJ- SERIES

Models with Input Rates 
from 45,000 to 120,000 BTU/HR
[13.19 to 35.17 kW]

(All Models 90% A.F.U.E.† or Above)

CLASSIC

®

90

HIGH EFFICIENCY
DOWNFLOW/
HORIZONTAL
GAS FURNACES

The Rheem

®

Classic

®

90 High Efficiency line of downflow/

horizontal gas furnaces are designed for utility rooms, clos-
ets, alcoves, attics or crawl spaces. The RGTJ is shipped in
the downflow configuration and is easily converted for hori-
zontal 

left-hand

airflow applications.

The design is certified by CSA.

Features

Low profile “34 inch” design is lighter and easier to handle
and leaves room for optional accessories.

Top electrical connections, left or right gas and conden-
sate drainage connections on downflow models.

Condensate drain for horizontal application provided
standard.

Integrated control board manages all operational functions
and provides hookups for an electronic air cleaner.

A slow-opening gas valve and a specially designed
inducer system make it one of the quietest furnaces on
the market today.

Galvanized steel cabinet.

Optional indoor or outdoor combustion air.

Control board diagnostics.

A variety of cooling coils and plenums designed to use with
the Classic 90 gas furnaces are available as optional acces-
sories for air conditioning models.

A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
of Energy test procedures.

Summary of Contents for CLASSIC 90 RGTJ- SERIES

Page 1: ...ofile 34 inch design is lighter and easier to handle and leaves room for optional accessories Top electrical connections left or right gas and conden sate drainage connections on downflow models Conde...

Page 2: ...direct drive multi speed blower motor Please note a thermostat is not included as standard equipment OPTIONAL EQUIPMENT See Accessory Page All models can be converted by a qualified distributor or lo...

Page 3: ...2 373 3 PSC 3 4 559 3 PSC 1 2 373 3 PSC MOTOR FULL LOAD AMPS 6 8 6 8 6 8 8 0 9 5 8 0 8 0 9 5 8 0 HEATING SPEED Med Low Low Med Med Low Med Med Low Med COOLING SPEED High High High High High High High...

Page 4: ...BACK TOP FRONT VENT 04 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 111 50 06 171 2 445 1611 32 415 155 8 397 2 51 165 8 422 137 8 352 0 0 0 1 25 2 51 0 117 53 07EM 171...

Page 5: ...ontal furnace may be installed for horizontal left hand air supply ONLY The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the furna...

Page 6: ...1010 477 1170 552 1300 614 990 467 1140 538 1255 592 940 443 1175 554 1395 656 12ERAJS 11 x 10 279 x 245 3 4 559 LOW MED HIGH 1590 750 1840 868 2315 1093 1565 738 1820 860 2250 1062 1540 727 1800 850...

Page 7: ...22 215 8 549 RXAA C187 RXAL B21BU 211 2 533 215 8 549 RXAA C188 RXAL B21BU HIGH ALTITUDE KIT F04 105 KBTU H F06 45 60 90 KBTU H F05 120 KBTU H F07 75 KBTU H FILTER RACK FILTER SIZES INCHES mm MODEL RG...

Page 8: ...ovincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product impro...

Reviews: