Generic Mode Network and Device Communication
45 (62)
11.3.4
Configuring the Device
D CONFIG
It is possible to save, load and show the configuration.
D CONFIG <operation>
Parameter
Parameter
Description
operation
SAVE
: Saves the current configuration, can take several seconds.
LOAD
: Loads the existing configuration.
SHOW
: Shows the configuration.
Example
D CONFIG SHOW
Possible Return Values
SAVE
Return Value
Description
I OK: CONFIG SAVE
Function succeeded
LOAD
Return Value
Description
I OK: CONFIG LOAD
Function succeeded
SHOW
Return Value
Description
I BT0=0, BT1=14 (1000 kBaud)
Values of bus timing registers. Name of configuration is
given in brackets.
I Bus coupling: HIGH
Bus coupling, exclusively HIGH supported
I Autostart: ON
Autostart mode ON/OFF
I STD filter list
I CAN Id: 1
I CAN Id: 4, RTR bit set
I STD filter enabled
Content of Standard ID filter list
I EXT filter list:
I CAN Id: 4, RTR bit set
I CAN Id: 7FFFF
I EXT filter disabled
Content of Extended ID filter list
I MAC-Slave: 001122334455 Can-Bluet.-
form.: binary, State: disconnected
Information about connection: MAC address, format of
CAN messages (ASCII, BINARY, OFF), connection status
(connected, disconnected)
I MAC-Master: C44619F9813A Can-Bluet.-
form.: off, State: connected
Information about Master
I TX-Buff. timeout: 0
Timeout value of transmitting buffer
I Passkey: 7388
Bluetooth passkey
I Visibility: 0
Bluetooth visibility
I MAC-Master List:
List with Master MAC IDs
I MAC-Slave List:
List with Slave MAC IDs
I OK: CONFIG SHOW
Function succeeded
CANblue II User Manual
4.01.0126.20000 EN 3.2