Configuration as Generic PC Interface or as Bridge
23 (62)
7.4.4
Setting the Transmitting Time
With the standard configuration, messages from the device are collected for up to 4 ms before
transmission. The minimum time between the transmission of two consecutive transmission
packets can be adjusted.
►
Adjust the time between two transmission packets with command
–
Transmitting is possible before a Bluetooth SPP packet is filled completely.
–
With timeout 0 the data is transmitted immediately. Protocol overhead is increased.
The size of a packet depends on the other node in the connection. CANblue II devices use data
packets of up to 669 bytes between themselves.
7.4.5
Reset to Factory Settings
Factory settings:
•
controller stopped
•
filters deleted
•
configuration deleted
•
master table deleted
•
transmitting time set to 4 ms
•
passkey set to 7388
•
visibility timeout set to 0
Observe, that preconfigured devices have different factory settings (preconfigured default
settings).
With Bluetooth Connection (Config)
►
To reset the device to factory settings, use command
Without Bluetooth Connection
Fig. 10
Button Reset to factory settings
►
Disconnect the device from the power supply.
►
Press and hold button
Reset to factory Settings
(
1
).
►
Connect the device to the power supply.
➨
CAN LED is flashing red and green.
►
Release button
Reset to factory Settings
(
1
).
➨
If Mode LED flashes several times, the configuration is reset to factory settings.
1
CANblue II User Manual
4.01.0126.20000 EN 3.2