  These units are warranted to be free of defective parts, materials, and

workmanship for a period of two years from the date of installation. This warranty is limited to the

repair or replacement of defective components only and does not apply to normal wear and tear.  If the 

factory’s service crews performed the original on-site placement and startup, then this warranty also 

includes labor.  Where labor is included, in lieu of sending a factory service crew to the site for minor 

repairs, Ixom may choose to send the replacement parts to the owner postage-paid and may pay the 

owner a reasonable labor allowance, as determined solely by Ixom, to install the parts.

GridBee air pumps, air compressors, control panels, and any optional accessories.

 These items 

are considered “buyout” items for Ixom, and as such include a warranty against defects in material and 

workmanship for one year from the date of purchase.  This warranty covers parts only, not labor.  Parts 

that are  determined by Ixom to be defective in material or workmanship under normal use during the 

one year warranty period will be repaired or replaced.  Shipping charges are the responsibility of the 

customer.

Terms applicable to all equipment. 

 This Limited Replacement Warranty is subject to the terms of 

Ixom’s General Terms and Conditions of Sale.  In the event of any inconsistency between the terms of 

this Limited Replacement Warranty and Ixom’s General Terms and Conditions of Sale, the terms of this 

Limited Replacement Warranty shall prevail to the extent of that inconsistency.

© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]

Warranty

GridBee AP Mixers Limited Replacement Warranty

1756_10067_20200420

O&M_AP7000_&_AP8000_10097_20200602 - 14

Summary of Contents for Medora AP7000

Page 1: ...2020 Ixom www medoraco com 866 437 8076 info medoraco com O M_AP7000_ _AP8000_10097_20200602 AP7000 AP8000 Operation Maintenance Manual...

Page 2: ...Tanks or Wastewater Treatment Processes Ixom equipment continues to be at the forefront as the 1 world leader for in situ water body treatment 2020 Ixom www medoraco com 866 437 8076 info medoraco com...

Page 3: ...You can avoid hazards by following these safety instructions and applying some ordinary common sense when operating or servicing this unit Keep in mind that full operator attention and alertness are r...

Page 4: ...ve ELECTRICAL HAZARD WARNING THIS EQUIPMENT CONTAINS HIGH VOLTAGE ELECTRICAL SHOCK CAN CAUSE SERIOUS OR FATAL INJURY ONLY QUALIFIED PERSONNEL SHOULD ATTEMPT PLACEMENT OPERATION AND MAINTENANCE OF ELEC...

Page 5: ...ith all relative OSHA and local regulations while installing and performing any maintenance to the mixer circulation equipment Key OSHA Compliance Standards that must be followed and not limited to ar...

Page 6: ...upply configuration please consult with factory Additional hardware and fittings may be required for different configurations AP7000 AP8000 Intake Plate with 18 hole in center Air Diffuser Intake Legs...

Page 7: ...dware and fittings may be required for different configurations AP7000 Intake Plate with 18 hole in center Air Supply connection point AP Housing Air Diffuser Intake Legs 100 Air Hose Intake Plate 16...

Page 8: ...tom In some applications suspending the unit from and structure above will work just be sure to use the dedicated lifting eyelets or eyebolts 1 2 Figure 1 AP Unit Pedestal Configuration 3 OPTIONAL HOS...

Page 9: ...taching float balls locate the 1 float chains and slide through the float pipe and add stop bolt at the top after measuring out desired manifold submergence depth The float ball will sit approximately...

Page 10: ...onverging streamlines to the AP Unit the water is forced upward toward the surface providing gentle mixing de stratification and surface renewal The AP Unit requires a minimal amount of supplied air T...

Page 11: ...t lowering in machine and then lower the machine slowly using the anchor chain to the desired depth 6 Plug in air unit and ensure that air is coming out of the machine You should see flow coming out o...

Page 12: ...100675 3 4 100673 1 100672 1 1 2 AP Machine Connection 2 Air Supply Connection Hardware Kit Part Number Size 100675 3 4 100673 1 100672 1 1 2 Tee Fitting Kit Part Number Size 100650 3 4 100652 1 1006...

Page 13: ...se part from Air Supply Hardware Kit Parts 1 2 2 7 Tee Fitting Connections Tee Fitting Kit Part Number Size 100650 3 4 100652 1 100654 1 1 2 Tee Fitting Kit included when customer supplies air source...

Page 14: ...ean from any scum buildup on the outside of the pipes that may contribute to preventing debris from passing through the unit Figure 1 Debris Passing Through AP Unit WINTER CONDITION RECOMMENDATIONS Fo...

Page 15: ...e or chain Floatation Accessory Floating option available float balls and short chain included to allow for adjustable intake depth with respect to water surface Maintenance Warranty Limited maintenan...

Page 16: ...items are considered buyout items for Ixom and as such include a warranty against defects in material and workmanship for one year from the date of purchase This warranty covers parts only not labor P...

Page 17: ...other related subjects as required by OSHA to perform the necessary work to install or remove SolarBee and GridBee equipment and are knowlegeable in the regulations and standards of OSHA If you feel...

Reviews: