IXIA AFD2 Manual Download Page 1

Ixia Platform Reference Manual Manual, Release 6.30

15-1

15

Chapter 15: 

Ixia IRIG-B Auxiliary 

Function Device 
(AFD2)

The IXIA Auxiliary Function Device 2 (AFD2) provides the means for accurate 
worldwide timing using Inter-Range Instrumentation Group (IRIG-B) 
technology. The ADF2 decodes the GPS 

satellite

s and time information and 

sends out a pulse to the Optixia chassis. The IXIA /AFD2 is shown in 

Figure 15-

1

.

Figure 15-1. Ixia AFD2

The IXIA AFD2 with integrated IRIG-B is designed to provide 12.5 MHz GPS 
clock with a programmable 80 ns sync pulse to the Optixia chassis.

The Ixia AFD2 IRIG-B receiver is controlled by an Ixia chassis through a USB 
port. Chassis timing is provided by connecting the Sync Out of the AFD2 to the 
Sync In of the chassis. This configuration then enables the chassis to operate as a 
subordinate in a virtual chassis chain, with the Ixia AFD2 as the master.

Figure 15-2

 on page 15-2 shows the AFD2 in operation with other chassis in a 

local chassis chain. Multiple local chassis chains can be collected through IRIG-
B into a virtual chassis chain.

Summary of Contents for AFD2

Page 1: ...IA AFD2 with integrated IRIG B is designed to provide 12 5 MHz GPS clock with a programmable 80 ns sync pulse to the Optixia chassis The Ixia AFD2 IRIG B receiver is controlled by an Ixia chassis thro...

Page 2: ...y latency measurements by subtraction of the transmit time stamp from the receive time stamp For large or very remote chassis chains the chassis chain properties provide an offset delay This delay is...

Page 3: ...e Source Synchronous IRIG B AFD2 IRIG B Mode B000 B000 is straight TTL serial output from the IRIG B receiver B120 B120 is amplitude modulation AM from the IRIG B receiver IRIG B Status Lock Status Lo...

Page 4: ...n of IRIG B as the timer source the IRIG B status is displayed In Figure 15 3 on page 15 3 the status is locked to the 1PPS signal coming from the IRIG B receiver In the chassis tree view of IxExplore...

Page 5: ...fore Attaching AFD2 Changing Time Source Any time the clock source is switched IxServer must be restarted When the chassis is switched from Synchronous time source to IRIG B or vice versa the followin...

Page 6: ...e there is no IRIG B information and the status is Unlocked in the Time Sources tab of Chassis Properties in IxExplorer Figure 15 3 on page 15 3 then one of the following conditions needs to be correc...

Page 7: ...d by one or more Ixia software users located likewise anywhere in the world Where IRIG B and CDMA sources are used all of the sources must have good quality time values in order for the trigger to be...

Page 8: ...B Tb Time Absolute T Time Error at any site Terr Lab Ta T1 Tb Lba Tb T2 Ta Delta L Lab Lba Delta L Ta T1 Tb Tb T2 Ta Delta L T1 T2 2 Ta Tb Delta L 2 Ta Tb If Ta T Terr and Tb T Terr Then Delta L 2 T...

Page 9: ...nd heartbeat is being generated by the IRIG B hardware Pwr OK Green The AFD2 power has been validated Lock Green Indicates that the internal PLL has locked to the 1PPS signal Testing is invalidated if...

Page 10: ...level shift pulse width coded with BCD CF control functions SBS IRIGB120 1kHz carrier sine wave amplitude modulated with BCD CF control functions SBS Clock 12 5 Mhz GPS System clock Pulse Width 80 ns...

Reviews: