EN
Embossing dark
Use the stamp for signing, and fasten the accompanying signing felt by means of the O-ring.
Connect the stamp by means of the black cable to the black socket and connect the red
cable to your workpiece.
The selector switch must be set to 3 (dark signing). Wet the signing felt carefully and evenly with
the appropriate electrolyte (ET). Position the signing stencil on the workpiece and press the
stamp vertically from above against the stencil, ensuring complete and uniform contact.
Move the stamp gently toencourage propagation of the electrolyte through the stencil. The
signing process is complete after 2 - 4 seconds.
Caution: Low-alloy steel, residual cooling liquid, drilling oil and similar substances can results in
chemical reactions.
Caution: Do not use the device in wet rooms; protect it against moisture and splash water.
17