Product information
- 7 -
CAUTION
・ After delivery open the product packaging and check to make sure that all included accessories are present and in good order.
・ Remember that the pump is heavy, so extreme care must be taken when lifting it. When lifting the pump using a chain hoist or
crane, be sure to lift the pump by the specified lift point(s). Be careful that nobody will pass under the pump when you lift it. It
will be very dangerous if the pump should fall.
・ When installing the accessories, please use the pipe sealing tape as provided for each threaded position, Also take care that
broken or shredded pipe sealing tape does not contaminate the liquid or Air inlets. Note that a contaminated airline may cause
failure of the pumps air switching unit.
!
!
!
!
・ Please install the air inlet Airline ball valve by referring to [Outside view] of [3.Name of parts and materials].
※ 1 The maximum applied air pressure of the plastic pump depends on the liquid temperature. (Table 3)
※ 2 DIAPHRAGMS. NBR/CR
0 ~ 70℃ [32-158 ℉ ]
TPEE/EPDM
0 ~ 80℃ [32-176 ℉ ]
FKM/TPO/PTFE
0 ~ 100℃ [32-212 ℉ ]
※ 3 Maasurement method of A-weighted sound pressure level is based on ISO 1996.
※ 4 Maasurement method of A-weighted sound power level is based on ISO 3744.
□ Pump Operation Manual
..........................................1
□ Service Book
................................................................ 1
□ How to use the Service Book
...............................1
□ Parts list
........................................................................ 1
□ Pump
................................................................................ 1
2.Accessories included with the pump
□ Airline ball valve
.......................................................... 1
□ Silencer
........................................................................... 2
□ Rubber feet
................................................................... 4
□ Bolt (M8 × 25)
............................................................4
□ Nut (M8)
......................................................................... 4
Model
TC-X800 □ -M
A □ , A □ J, S □ , S □ J, F □ , F □ J
[A □ N, A □ A, S □ N, S □ A, F □ N, F □ A]
AT, ATJ, ST, STJ, FT, FTJ
[ATN, ATA, STN, STA, FTN, FTA]
G □ J
[G □ A]
GTJ
[GTA]
Liquid port
Rc 3 or Equivalent to JIS Flange 10K80A
[NPT 3 or Equivalent ANSI Flamge 150 3B]
Equivalent to JIS Flange 10K80A
[Equivalent ANSI Flamge 150 3B]
Material ・ Weight
Table 1
Operating pressure ※ 1
0.1 ~ 0.85 MPa
[14-125 psi]
0.15 ~ 0.7 MPa
[22-100 psi]
0.1 ~ 0.7 MPa
[14-100 psi]
0.15 ~ 0.7 MPa
[22-100 psi]
Max discharge pressure
0.85 MPa [125 psi]
0.7 MPa [100 psi]
Discharge volume/Cycle
6800 mL
3200 mL
6800 mL
3200 mL
Max Discharge volume
850 L/min
[224.6 Gallon/min]
640 L/min
[169.1 Gallon/min]
800 L/min
[211.4 Gallon/min]
640 L/min
[169.1 Gallon/min]
Max air consumption
5500 L/min(ANR)
[194.21 SCFM]
5900 L/min(ANR)
[208.33 SCFM]
5700 L/min(ANR)
[201.27 SCFM]
5900 L/min(ANR)
[208.33 SCFM]
Max solid size
10 mm or less
10 mm or less
Limitation of viscosity
Self-priming 3 Pa ・ s or less Force In 8 Pa ・ s or less
Ambient temperature
0 ~ 70 ℃ [32-158 ℉ ]
Liquid temperature
※ 2
0 ~ 60 ℃ [32-140 ℉ ]
Dimensions
Table 2
A-Weighted sound pressure level ※ 3
90dB
85dB
A-Weighted sound power level ※ 4
97dB
95dB
Summary of Contents for TC-X400A M Series
Page 29: ...28 memo...
Page 32: ...2021 11...