■ Flow based control (when using a pulse signal as a start signal)
Use the pulse controller or user's PLC to program a discharge and a suction flow rate as well as a pause time
[T1] of 0.5 sec or more between the end of a discharge process and the start of a suction process and a wait-
ing time (at least 1/2 of the time taken to finish suction process per set flow rate) [T2] between the end of the
suction process and the start of the next discharge process. The programmed behaviour starts at an input of
pulse signal.
Pump setting
Discharge
process
Suction
process
Valve delay (user-selectable)
Pause time [T1] : 0.5 sec or more
Waiting time [T2] : 1/2 of suction time or more
Precedent valve close (user-selectable)
Pump behaviour
Pulse signal
(from pulse controller/PLC)
Home sensor output signal
(from pump)
Control signal of discharge-
line air-operated valve
(opens during signal input)