40
Wear part replacement
Before replacement
First release pressure from the pump head.
Stop the pump operation.
Rotate the adjusting screw two revolutions anticlockwise to open
the air vent port.
NOTE
Do not rotate it three revolutions or more. Otherwise, the adjusting screw may
come off with solution spray.
Check the discharge line and the pump head are depressurized.
Liquid pressure is released from the air vent port in the form of solution
spray.
NOTE
If pressurized liquid is not expelled, run the pump with an opened air vent port
until pressure is removed.
1
2
3