Technical specifications  

 

SCplus 15

 

SCplus 25 A 

SCplus 40 A 

SCDplus 15A 

SCDplus 25A 

SCDplus 40 A 

SCDplus 40 A/48 V 

System voltage 

12/24 V 

12/24 V 

12/24 V 

12/24 V 

12/24 V 

12/24 V 

48 V 

Max. solar panel voltage 

50 V 

50 V 

50 V 

50 V 

50 V 

50 V 

90 V 

Max. solar panel / load current 

15 A 

25 A 

40 A 

15 A 

25 A 

40 A 

40 A 

Estimated solar panel power 

180/360 W 

300/600 W 

480/960 W 

180/360 W 

300/600 W 

480/960 W 

1920 W 

Cut-off voltage, SLA 

14,0/28,0 V 

56 V 

Cut-off voltage, GEL 

14,1/28,2 V 

56,4 V 

Cut-off voltage, AGM 

14,7/29,4 V 

58,8 V 

Cut-off voltage, LiFePO4 

14,2/28,4 V 

56,8 V 

Trickle charging, SLA/GEL 

13,7/27,4 V 

54,8 V 

Trickle charging, AGM/LiFePO4 

13,8/27,6 V 

55,2 V 

Deep discharge protection 

10,5/21,0 V 

42,0 V 

Reset voltage 

12,0/24,0 V 

48,0 V 

Fuse 

15 A 

25 A 

40 A 

15 A 

25 A 

40 A 

40 A 

Current consumption, activ 

25 mA 

25 mA 

25 mA 

50 mA 

50 mA 

50 mA 

50 mA 

Current consumption, standby 

< 10 mA 

Operating temperature 

-20 °C to +60 °C 

Temperatur sensor 

ja (extern) 

PC interface 

USB (Typ B) 

Max. efficiency 

98% 

Housing 

plastic 

Dimensions 

19,0 x 10,5 x 5,5 cm 

Weight 

0,46 kg 

0,46 kg 

0,48 kg 

0,52 kg 

0,52 kg 

0,54 kg 

0,54 kg 

Part number 

200038 

200039 

200040 

200041 

200042 

200043 

200044 

 
 
 
 
 
 
 

 

GB - Environmental Protection Notice 

At the end of its useful life, this product must not be disposed of together with normal household waste, but has 
to be dropped off at a collection centre for the recycling of electrical and electronic devices. This is indicated by 
the symbol on the product, on the instruction manual or on the packaging. 
The materials of which this product is made are recyclable pursuant to their labelling. With the reuse, the 
recycling of the materials or other forms of scrap usage you are making an important contribution to the 
protection of the environment.  
Please ask your local administration office for the appropriate disposal centre. 

 

Technical specifications subject to change.  We assume no liability for typographical errors.  

IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, 92242 Hirschau 

Phone 09622-719910, Fax. 09622-7199120      e-mail: [email protected]   Internet: www.IVT-Hirschau.de 

 
 
 

 

Summary of Contents for SCDplus

Page 1: ...Solar Controller SCplus SCDplus BEDIENUNGSANLEITUNG Seite 2 9 INSTRUCTION MANUAL page 10 17 NOTICE D UTILISATION c t 18 25 GEBRUIKSAANWIJZING pagina 26 33...

Page 2: ...geh rt nicht in Kinderh nde Stellen Sie sicher dass das Ger t zu jeder Zeit kindersicher betrieben und gelagert wird Wartungs Einstellungs oder Reparaturarbeiten d rfen nur von einem Fachmann Fachwerk...

Page 3: ...barer Temperaturkoeffizient Programmierbares Ein und Ausschalten des Lastausganges Energiez hler Funktionen mit PC Software einstellbar Aufzeichnung und berwachung mittels PC Software Funktionsbeschre...

Page 4: ...armodul an den entsprechenden Schraubklemmen 12 am Solar Controller 3 Anschluss der Last Verbinden Sie schlie lich die DC Verbraucher mit dem Lastausgang 10 des Solar Controllers Die Anschlussbelegung...

Page 5: ...Time das aktuelles Datum Date die Temperatur am Sensor T der aktuell eingestellte Temperaturkoeffizient COMP Abb 7 Abb 8 Hinweis Wenn durch fehlende oder zu geringe Solarleistung keine Ladung der Bat...

Page 6: ...C SCD Series Solar Charger angezeigt 4 Klicken Sie mit der rechten Maustaste auf das angezeigte Ger t Treibersoftware aktualisieren 5 W hlen Sie Auf Computer nach Treibersoftware suchen 6 W hlen Sie d...

Page 7: ...halten des Lastausganges definiert werden Hierzu stehen die beiden Eingabefelder Load on time und Load off time zur Verf gung Einstellung des Tiefenentladeschutzes Deep disch Settings Durch Einstellun...

Page 8: ...O4 Lithium Eisen Phosphat Batterie Die Solaranlage arbeitet nicht richtig m gliche Ursachen und Abhilfe Achtung In Batterien sind gro e Energiemengen gespeichert Bei Kurzschluss k nnen diese Energieme...

Page 9: ...mperaturf hler ja extern PC Schnittstelle USB Typ B Max Effizienz 98 Geh use Kunststoff Abmessungen 19 0 x 10 5 x 5 5 cm Gewicht 0 46 kg 0 46 kg 0 48 kg 0 52 kg 0 52 kg 0 54 kg 0 54 kg Art Nr 200038 2...

Page 10: ...is inadmissible This device is no toy and must not be used by children Please ensure childproof operation and storage of the device at any time Maintenance installation or repair works may only be pe...

Page 11: ...veral charging profiles can be selected SLA AGM GEL LiFePO4 User Adjustable temperature coefficient Switching the load output on and off can be programmed Energy meter Functions can be adjusted with P...

Page 12: ...e symbols on the solar controller or the illustration see connections and operating elements Notes Please observe correct polarity when connecting the DC consumers Make sure that the load output of th...

Page 13: ...the following options to cancel the standby mode automatically by sufficient solar power push the Load button 14 push the button 2 only in SCD models Standard device settings at 12V battery system Cha...

Page 14: ...5 Select Browse my computer for driver software 6 Select the folder which contains the driver file SC_series_usb inf and confirm by clicking Next 7 Skip appearing safety instructions Install this dri...

Page 15: ...or on at pre programmed times If the timer function is selected any time may be defined for switching the load output on or off The two input fields Load on time and Load off time are available for t...

Page 16: ...osphate battery The solar system does not work correctly possible causes and remedies Attention Batteries contain large amounts of energies In case of short circuit these energy quantities can be rele...

Page 17: ...a extern PC interface USB Typ B Max efficiency 98 Housing plastic Dimensions 19 0 x 10 5 x 5 5 cm Weight 0 46 kg 0 46 kg 0 48 kg 0 52 kg 0 52 kg 0 54 kg 0 54 kg Part number 200038 200039 200040 200041...

Page 18: ...rs de port e des enfants Les op rations d entretien de r glage ou de r paration doivent imp rativement tre effectu es par un technicien atelier professionnel Pour toute r paration il ne faut utiliser...

Page 19: ...ques D tection automatique de la tension syst me chez 12 24 V R gulation de la charge en fonction de la temp rature Protection r glable contre une d charge profonde avec pr avis Interruption du module...

Page 20: ...rie Connectez la batterie aux bornes vis 11 du r gulateur solaire pr vues cet effet N utilisez que des c bles section appropri e afin de minimiser la baisse de la tension et l chauffement des c bles L...

Page 21: ...Les sorties de chargement et de charge du r gulateur solaire sont prot g es par des fusibles enfichables facilement accessibles Attention Le fusible doit exclusivement tre remplac par un fusible du m...

Page 22: ...n du logiciel Installation de l application 1 Double cliquez sur le fichier de configuration SCControl msi afin de lancer l installation du logiciel Ce fichier peut galement servir d sinstaller le log...

Page 23: ...ings La sortie de charge dispose de quatre modes de service N A D s que la tension de d charge finale est atteinte la sortie de charge s arr te durablement AUTO D s que la tension de d charge finale e...

Page 24: ...de diagrammes De plus la date actuelle et l heure peuvent tre synchronis es et le compteur d nergie peut tre remis z ro Pour lire les param tres actuels m moris s dans le dispositif cliquez sur le bo...

Page 25: ...e LED tat s allume en rouge Protection d charge prof activ e Attendre recharge R duire la charge de la batterie La batterie n est pas compl tement recharg e Profil de charge s lectionn erron Ajuster l...

Page 26: ...n Dit toestel mag niet in handen van kinderen terechtkomen Zorg ervoor dat het toestel altijd buiten het bereik van kinderen gebruikt en bewaard wordt Onderhouds instel of reparatiewerkzaamheden mogen...

Page 27: ...profielen selecteerbaar SLA AGM GEL LiFePO4 User Instelbare temperatuurco ffici nt Programmeerbaar in en uitschakelen van de belastingsuitgang Energiemeter Functies met pc software instelbaar Registra...

Page 28: ...e energielaadregelaar moeten in dezelfde ruimte en op een geringe afstand van elkaar worden aangebracht 5 Aansluiting van de zonne energiemodule zonnecellen Verbind de zonne energiemodule met de overe...

Page 29: ...ceerd en overgenomen Afb 2 Tijdens deze fase verschijnen de volgende meldingen op het display Afb 1 Afb 2 Afb 3 Opgelet Tijdens deze initialisatiefase mogen geen drukknoppen worden ingedrukt Op In het...

Page 30: ...de installatieprocedure is het bestand SCControl exe op het bureaublad te vinden installatie van het stuurprogramma van het toestel 1 Verbind de zonne energielaadregelaar met behulp van de USB kabel...

Page 31: ...settings Voor de belastingsuitgang staan vier werkwijzen ter beschikking N A De belastingsuitgang schakelt permanent uit als de minimale eindontlaadspanning bereikt wordt AUTO De belastingsuitgang sc...

Page 32: ...n afdrukken Daarenboven kunnen de huidige datum en het tijdstip gesynchroniseerd worden en de energiemeter weer op nul gezet worden Om de momenteel in het apparaat opgegeven parameters te selecteren k...

Page 33: ...us led brandt rood Bescherming tegen diepontlading actief Oplading afwachten Belasting van de accu verminderen De accu wordt niet volledig opgeladen Verkeerd laadprofiel gekozen Laadprofiel aanpassen...

Page 34: ...34 Notizen...

Page 35: ...35 Notes...

Page 36: ...36...

Reviews: