35
Energy saving tips
HMC300 – 6 720 813 192 (2014/10)
Menu:
System information
The information under respective menu options is only shown
if the corresponding system parts are installed. If 2 heat pumps
have been installed you must choose between heat pump 1 and
2.
7
Energy saving tips
Heating/cooling set low
•
Use the optimised mode. Set the required room
temperature to your personal comfort level. The heat pump
saves most energy if it works continuously.
•
Open the thermostat valves completely in all rooms.
Increase the temperature on the control unit only when the
required room temperatures has not been reached after a
long period. Only close the thermostat valve in a room if it
gets too hot just in that room.
•
If there is a room unit in the system the room temperature
can be optimally controlled. Avoid the effect of induced
heat (e.g. from sunlight or stove). Otherwise there can be
unwanted variations in the room temperature.
•
Do not place any large objects directly in front of radiators,
e.g. a soffa (minimum 50 cm gap). The heated or cooled air
will otherwise not be able to circulate and heat up or cool
the room.
•
Do not set the temperature too low to start the cooling.
Cooling of the home also consumes energy.
Air properly
Open the windows completely for a short time instead of
allowing them to stand ajar. If windows are left ajar heat
dissappears continuously from the room without the air in the
room become much better.
Close the thermostat valves while airing the room.
Heating of hot water according to need
•
Use the time program for automatic operation of heating
hot water.
•
Set the lowest possible hot water temperature. This saves
a lot of energy, without significantly reducing hot water
comfort.
Menu options Description
Status
outdoor unit
The outdoor unit is switched off or in
operation for different reasons. This menu
option shows the following operating status
for this:
Off
;
Heating
;
Cooling
;
DHW
;
Pool
;
Pool/heating
;
Defrosting
;
Alarm
Status
additional
heat
Additional heat is switched off or in
operation for different reasons. This menu
option shows the following operating status
for this:
Off
;
Heating
;
DHW
;
Pool
;
Pool/
heating
;
Alarm
Immersion
heater
heating
output
Actual via the output supplied by the
additional heat in kW (0.1– 15.0)
Status mixed
additional
heat
•
Extra heat source
: Additional heat is
On
or
Off
.
•
Mixing valve
: If the output of the heat
pump is insufficient, hot water is
supplied from the additional heat to the
heating system via a shunt. The following
then applies: 0% = no additional heat
supplied – 100% maximum additional
heat output supplied.
Electricity
company
block
1)
1) Not used in Sweden.
If
On
is shown the system is working with a
limited electric output. If
Off
is shown here
the system can work with full electric output.
Additional
heat in hot
water heater
Additional heat hot water heating is
On
or
Off
.
Actual mode
Actual operating mode for selected heating
circuit (
Heating
,
Idling
,
Cooling
)
Table 38 System information