Ivoclar Vivadent SR Ivocap Operating Instructions Manual Download Page 5

5

1.1 Introduction

The SR Ivocap System is an
injection technique which
has been especially 
developed to compensate
curing shrinkage. Heat/
pressure curing allows
shrinkage of the acrylate
during polymerization to be
compensated by inflowing
material.

The SR Ivocap injection
technique, therefore, permits
the fabrication of high
quality products with
excellent physical properties.

Indication

• Complete dentures
• Partial dentures
• Relines
• Orthodontic appliances
• Occlusal splints

Contraindication

Keep unpolymerized
material away from

intraoral areas. Do not use
the material if the patient is 
known to be allergic to any
of the ingredients listed.

The SR Ivocap System
may only be
operated by trained
personnel.

1.2 Signs and symbols

The signs and symbols in
these Operating Instructions
facilitate the finding of
important points and have
the following meaning:

Risks and dangers

Important 
information

Contraindication

1.3 Notes regarding

the Operating
Instructions

These Operating

Instructions must 
be read prior to
working with the 
SR Ivocap System.

Equipment concerned: 
SR Ivocap System Target
group: Dental technologists

The Operating Instructions
facilitate the correct and
economic use of the 
SR Ivocap System.

These Operating Instructions
are divided in several, clearly
structured chapters. They
should enable you to locate
specific topics quickly and
easily.

The SR Ivocap material is not
described in these instruc-
tions. Please refer to the
corresponding Instructions
for Use of the Ivocap
material.

The inform your about
risks/dangers, important
information, and contraindi-
cations, these Instructions
contain corresponding signs/
symbols (pictographs) to
mark important paragraphs.

We recommend keeping the
Instructions in a safe place
near the equipment to have
immediate access to the
information if necessary.

Should you lose the 
Operating Instructions, extra
copies can be ordered at a
nominal fee from your local
Ivoclar Vivadent Service
Center.

1. Introduction / Signs and Symbols

Summary of Contents for SR Ivocap

Page 1: ...Operating Instructions SR Ivocap Equipment System...

Page 2: ...2...

Page 3: ...lation 8 4 1 Unpacking and checking the contents 4 2 Selecting the location 5 Operation 9 5 1 Operating elements at the pressure apparatus 5 2 Operating elements at the clamping frame 6 Procedure 10 6...

Page 4: ...eter A3 Extrusion piston A4 Vise shank A5 Safety loop B Clamping frame JS3 B2 Thrust collar with lever B3 Pressing plate C Flask C1 Flask half M C2 Flask half W C3 Flask lid C4 Injection funnel D Caps...

Page 5: ...rmation Contraindication 1 3 Notes regarding the Operating Instructions These Operating Instructions must be read prior to working with the SR Ivocap System Equipment concerned SR Ivocap System Target...

Page 6: ...y risk resulting from failure to observe these Instructions Further instructions to assure proper use of the system The instructions regulations and notes in these Operating Instructions must be obser...

Page 7: ...as been especially developed to compensate curing shrinkage Controlled polymerization allows shrinkage of the material during polymerization to be compensated by inflowing material The SR Ivocap injec...

Page 8: ...poses 4 2 Selecting the location The diagram below depicts one possible installation Important information For safety reasons the installation of the pressure power and water connections may only be c...

Page 9: ...sed horizontal position 5 2 Operating elements on the clamping frame Thrust collar with lever B2 Operation 1 Thrust collar with lever closed push to the right until it stops 2 Thrust collar with lever...

Page 10: ...oling in a cold water bath at least 30 minutes the injection pressure must be maintained for at least 20 minutes thereof 3 2 1 Compressed air 6 bar Water level Pressure apparatus Capsule Flask Mark fo...

Page 11: ...air connection before maintenance and cleaning 7 1 Monitoring and maintenance The time for these maintenance procedures depends on the frequency of use and work ing habits of the users For that reaso...

Page 12: ...tes for users Flask margins are not clean plaster residue on the injection funnel The model should be trimmed prior to investment Clamping frame is not correctly positioned i e in the centre of the pr...

Page 13: ...Acceptable operating conditions Acceptable humidity range Maximum relative humidity at 31 C 87 F gradually decreasing to 50 at 40 C 104 F condensation excluded Acceptable ambient pressure The unit is...

Page 14: ...14...

Page 15: ...15...

Page 16: ...627 33 99 Fax 57 1 633 16 63 www ivoclarvivadent com Ivoclar Vivadent SAS B P 118 F 74410 Saint Jorioz France Tel 33 450 88 64 00 Fax 33 450 68 91 52 www ivoclarvivadent fr Ivoclar Vivadent GmbH Dr Ad...

Reviews: