WARNING! 

Removing the valve from service or disassembling the valve while there is pressure in the valve body 

may result in serious injury or damage to the valve. 

Relieve pipeline pressure and lockout the isolation valve before servicing the valve. 

 

SECT: 1.10

 

MAINTENANCE

 

(a)

 

Disassembly Procedure 

1.

 

Close isolation valve (1)

 

2.

 

Open  gauge  port  ball  valve  until  pressure  is 
released (2) 

 

3.

 

Once  Pressure  is  released,  loosen  bolts,  nuts  and 
washers (3)

 

4.

 

Remove top flange assembly (4) and check sealing 
O-ring for damage

 

5.

 

Remove  multi-orifice  Anti-Surge  Float  (5)  and 
check sealing O-ring for damage

 

6.

 

Remove  Control  Float  (6)  and  Nozzle  Float  (7) 
assembly from valve body. 

 

7.

 

The valve is now dis-assembled.  Clean top flange, 
anti-surge  float  and  control  float  by  rinsing  with 
water. Clean interior of valve body.

 

8.

 

Dis-assemble  Nozzle  Float  (7)  from  lower  Control 
Float (6). 

9.

 

Remove  the  Nozzle  Float  (7)  from  the  Nozzle  (8).  
To hold Nozzle (8) from rotating, insert a flat screw 
driver  thru the  center  hole  in  the  Nozzle  Float  (7) 
into  the  slotted  end of  the  Nozzle  (8)  OR  through 
one  of  the  slots  in  the  Upper  Nozzle  Assembly 
Plate (9) and unscrew the Nozzle Float (7). 

10.

 

Use  a  screw  driver  to  dis-assemble  the  Upper 
Nozzle Assembly Plate (9), Lower Nozzle Retaining 
Plate (10) and the Nozzle (8) from the Control Float 
(6).    Inspect  the  small  orifice  in  the  Nozzle  (8)  for 
blockage  and  the  Nozzle  Seat  (11)  for  damage  or 
permanent deformation.  Rinse Nozzle (8) in clean 
water.

 

 

 

 

Summary of Contents for Vent-Tech SWG B Series

Page 1: ...ernationalvalve com Operation and Maintenance Manual VENT TECH MODEL SWG SERIES C B V AND N MODEL SWG SERIES C B V AND N WASTE WATER AIR RELEASE AND VACUUM RELIEF VALVES Revised 09 13 13 Vent Tech Sew...

Page 2: ...cuum relief valve for sewage duty Vent Tech manufactured by International Valve Marketing IVM LLC was incorporated in 2009 for the express purpose of expanding and improving the technological advances...

Page 3: ...age and file a claim with the carrier if damage is apparent Carefully unload all valves to the ground without dropping The valve should be lifted by the body the sealing flange fasteners or where appl...

Page 4: ...up Discharge of air gas from pressurized pipeline Surge control to prevent the development of hydraulic transients during start up and pressure surges Full port high volume air intake for vacuum relie...

Page 5: ...downtime Order parts from your local Vent Tech sales representative or directly from International Valve Marketing When ordering parts please refer to the following If the valve has a Vent Tech name...

Page 6: ...RK V SWG08ORK N 10SWG SWG10ORK C SWG10ORK B SWG10ORK V SWG10ORK N 12SWG SWG12ORK C SWG12ORK B SWG12ORK V SWG12ORK N O Ring Repair Kit Part Numbers Valve Size Series C Series B Series V Series N 02SWG...

Page 7: ...el SWG Series C B V N Air relief valves should be made with careful review by the system engineers Critical elements of a successful air relief valve installation are recommended below 1 Install isola...

Page 8: ...ice Anti Surge Float 5 and check sealing O ring for damage 6 Remove Control Float 6 and Nozzle Float 7 assembly from valve body 7 The valve is now dis assembled Clean top flange anti surge float and c...

Page 9: ...O clock 3 O clock and 9 O clock fashion by hand until all bolt nut assemblies are hand tight Tighten nuts and bolts again with a wrench Locate washers on the nut side of the flange 10 Follow standard...

Page 10: ...runs clear Consult local requirements for handling of pipeline emissions An example maintenance worksheet is included in the Addendum at the end of this manual d Troubleshooting Air Valve Problems Th...

Page 11: ...e float Valve body is now pressurized Buoyancy lifts control float Seats control and nozzle floats against anti surge float Valve body is now pressurized Buoyancy lifts control float Seats control and...

Page 12: ...nistrative fees or any costs incurred in removing or reinstalling the Product to coverage for any claims submitted to Seller after expiration of the applicable warranty time period described in this W...

Page 13: ...d nozzle plates necessary to the repair of products delivered under this warranty free of charge FOB factory for a period of ten 10 years The foregoing remedy shall constitute the sole and exclusive r...

Page 14: ...171 3 8 16 236 201 247 210 1 8 286 243 299 254 3 8 24 259 220 271 230 1 14 259 220 270 230 7 16 14 376 320 393 334 1 1 8 7 413 351 432 367 7 16 20 400 340 418 355 1 1 8 12 390 332 408 347 Bolt Size A2...

Page 15: ...and remnants of the sewage media However this debris and or FOG should be monitored so it does not interfere with seating of any O rings or with the movement of any of the floats Over time there will...

Reviews: