Lubricate the drive pin with IVEK Spindle Bearing Lubricant (IVEK part number 052046) prior to assembly. Failure 
to lubricate the drive pin may result in damage to the Pump Module and Motor/Base Module.

 

 

1.  Rotate the spindle on the Motor/Base Module so the spherical bearing is at the 3 O'clock position. 

 

2.  Extend the piston, which is housed in the Pump Module, approximately 2/3 of the way out of the cylinder. 

 

3.  Slide the drive pin, which is pressed into the piston end cap, into the center bore of the spherical bearing. 

 

4.  Position  the  Pump  Module  on  the  swing  plate  with  the  locating  pin  of  the  swing  plate  inserted  into  the  slot  of  the 

Pump Module mounting key. 

5.  Secure the Pump Module to the swing plate by tightening the two #10 socket head cap screws on the swing plate. 

 

NOTE

 

 

Figure 7.3 shows the inlet orientation of the Pump Module on both the Single Ended and Double Ended 
Motor/Base Modules.

 

 

7.4 

OPTIONS 

 

IVEK Corporation offers a variety of options to best meet the 

customers’ needs. Following is a list and description of available 

options for the Pump Module. Refer to the Title Section of this manual for the list of options provided with this system.

 

 

7.4.1

 

Special Piston/Cylinder Bore Clearances or Modifications

 

 

For certain applications, special clearances are required for the piston/cylinder bore. IVEK Corporation determines these 
clearances by performing application tests using the application fluid. Contact IVEK Corporation for more information.

 

 

For certain applications, special machined modifications are required for the piston/cylinder. IVEK Corporation determines these 

modifications by performing application tests using the application fluid. Contact IVEK Corporation for more information.

 

 

 

 
 

Inlet

 

 

Note connector

 

 

position

 

Inlet

 

 

 

Inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Figure 7.3 Split Case Pump Module Orientation 

 

Summary of Contents for SPLIT CASE PUMP MODULE 092122 Series

Page 1: ...inder Bore Clearances or Modifications 7 4 7 4 2 Rinse Gland 7 5 7 4 3 Cartridge Heater Ports Cartridge Heaters 7 5 7 4 4 Fittings 7 5 7 5 Maintenance 7 5 7 5 1 Preventative Maintenance 7 5 7 5 2 Stor...

Page 2: ...s of the pump head relative to the axis of the motor drive shaft This displacement range is infinitely adjustable within the pump specifications refer to Table 7 1 The displacement adjustment is easil...

Page 3: ...The combination of the ceramic material s mechanical and thermal stability allows it to be machined and operated with a close running clearance This means that no compliant dynamic seals are needed e...

Page 4: ...plate NOTE Figure 7 3 shows the inlet orientation of the Pump Module on both the Single Ended and Double Ended Motor Base Modules 7 4 OPTIONS IVEK Corporation offers a variety of options to best meet...

Page 5: ...are available with the Pump Module Chapter 9 lists the IVEK part numbers for the available fittings associated seals and sleeves when required Not all fittings shown are applicable to the Split Case...

Page 6: ...d store the component parts disassembled until the pump is again required The instructions for disassembling the Pump Module are found in Section 7 5 5 of this chapter NOTE If applicable the disassemb...

Page 7: ...Loosen the two 10 socket head cap screws securing the Pump Module to the swing plate 3 Lift the Pump Module and pull up and away from the swing plate until the piston fabrication is approximately 2 3...

Page 8: ...clockwise direction 3 Finish tightening using spanner wrench supplied 7 5 5 3 Key Figure 7 5 Item 6 Disassembly 1 Remove the Pump Module from the Motor Base Module as described in section 7 5 5 1 2 R...

Page 9: ...pump fabrication 3 and secure with two socket head cap screws 10 2 Place cylinder locating pin 5 in position and gently press in until it contacts key 6 3 Install the cylinder and piston fabrication...

Page 10: ...isassembly 1 Remove the Pump Module from the Motor Base Module as described in section 7 5 5 1 2 Remove the fitting sets 12 from split case pump fabrication 3 by placing the spanner wrench provided wi...

Page 11: ...and what liquids are being pumped It may also be necessary to return the Controller and Motor Base Modules along with the Pump Module should readjustment of the pump drive components be required to fr...

Page 12: ...ze Zirconia 005 D Size Alumina 006 D Size Zirconia 013 16mm Size Alumina 101 B Size Alumina W Gland 102 B Size Zirconia W Gland 103 C Size Alumina W Gland 104 C Size Zirconia W Gland 105 D Size Alumin...

Page 13: ...ne of the above solves the problem contact IVEK technical support for assistance Fluid is leaking from front of Leaky seals Inspect for scratches or grit clean or replace if pump necessary End cap wil...

Page 14: ...SPLIT CASE PUMP MODULE Page 7 14 15 July 2019 IVEK Corp P07R002P Figure 7 7 Split Case Pump Module Sheet 1 of 3 1 2 9 14 11 13 3 4 7 12 12 3 5 6 10...

Page 15: ...brication W O Heater Ports 1 2 6 092074 02 Key Locating Split Case Pump 316 SST 1 3 3 092065 2 Split Pump Case Fabrication W Heater Ports 1 3 6 092074 01 Key Locating Split Case Pump 420 SST 1 4 3 092...

Page 16: ...re 7 7 Split Case Pump Module Sheet 2 of 2 Model Dwg Index Part Tab Description Qty 103 7 022218 103 C Size Alum W Gland 1 104 7 022218 104 C Size Zirc W Gland 1 105 7 022218 105 D Size Alum W Gland 1...

Page 17: ...K 10 27 08 Per DCR N corrected Nm conversion for Castellated Sleeve torque J 2 10 04 Updated Per DCR N 9909 I 8 28 03 Updated Per DCR N 9662 H 1 8 03 Updated Per DCR N 9292 Changed gland Ceramics Par...

Page 18: ...T DOCUMENT CARRIER SHEET Document Number P07R002P Description Split Case Pump Module Date Submitted July 15 2019 Reviewed By Date Delivered Date Returned Signature Engr Mgr IS Mgr Sales Mgr Operations...

Reviews: