IVDT SkidWeigh ED7 Series Installation & Calibration Manual Download Page 8

 

-  Turn on ignition switch                                                                                                                                                         

-

 Display will show IVDT logo, software version and serial number for the moment.                                                                                                           
- With forks on the ground system display will show normal weighing mode window 

Integrated Visual Data Technology Inc.   3439 Whilabout Terrace, Oakville, Ontario, Canada  L6L 0A7  

    

   Operator Usage Guide 

-

WEIGHING PROCEDURE 

                                                                                                                                                

- Insert the forks into the pallet or product to be weighed                                                                                           
- Lower the loaded forks to the ground                                                                                                                           
- Lift the load approx. 2” o

 the ground using the hydraulic lift lever 

same as during normal use.                                                                    
- Do not use lift lever by lifting load “slow”.  

                                         

Within few seconds load weight will be shown on LCD display.

 

   

 Accumulative Load Weight Total 

- When load is lifted and display will shows the load weight.                                                                           

To add the load to the accumulative total tap on

 Add

 icon. 

- In addition to the current last load weight the accumulative load weight total will be shown on display. 
- When finished with accumulative load weight total procedure, on last load weight shown on display, press 

Send 

icon to reset accumulative load weight total function. 

- System will automatically show overload

Normal weighing mode LCD window

Summary of Contents for SkidWeigh ED7 Series

Page 1: ...n Calibration Manual SkidWeigh ED7 Series Lift Truck Onboard Check Weighing Scale 5 7 Touch Screen ED7 Ver 3 2 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Home Page ...

Page 2: ...indicator pressure transducer and any other associated cables are securely mounted and do not impede any of the vehicle s controls Use care when routing the components cables Route the cables where they will be protected Use commonly accepted install practices for after market industrial vehicle electronic devices The installation of the SkidFleet systems should only be performed by an acknowledge...

Page 3: ...em check weighing operational principal is based on the hydraulic pressure transducer mounted in the vehicle lifting hydraulic circuit that will automatically activate the weighing cycle specific algorithm every time a skid load is lifted just above the ground The increase in pressure is converted in an electronic signal at the sample rate of 16000 readings which is converted into a load weight re...

Page 4: ...l to ensure tight fit Selecting the mounting location for digital indicator Use the mounting bracket to fasten digital indicator on the vehicle dashboard side railing or preferably on the top of the operator guard There are many examples of mounting locations that will depend on the vehicle model However additional mounting items such as a flat brackets may be needed to help secure the unit to upp...

Page 5: ...splay will show digital readout change as forks are lifted and lowered If the above test is valid than the system pressure transducer electrical connections are done right Note If the readout shows 0 or only high readout number value over 65000 than check wiring connection to the pressure transducer or replace pressure transducer Date Time Set Up Tap on the icon Clock More shown on home page Tap o...

Page 6: ...ght in pounds and enter that value accordingly The same would apply if you want the system to show load weight in kilograms Have known load weight nearby Calibration Note In our example a known calibration load weight is 4000 Integrated Visual Data Technology Inc 3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 Turn ignition switch to on position LCD display will show standard weighing mode ...

Page 7: ...3439 Whilabout Terrace Oakville Ontario Canada L6L 0A7 1 2 3 4 5 6 7 8 The SkidWeigh ED7 calibration is done The SkidWeigh ED7 overload warning is set With calibrated load weight lowered to the ground system is calibrated and ready for use ...

Page 8: ... using the hydraulic lift lever same as during normal use Do not use lift lever by lifting load slow Within few seconds load weight will be shown on LCD display Accumulative Load Weight Total When load is lifted and display will shows the load weight To add the load to the accumulative total tap on Add icon In addition to the current last load weight the accumulative load weight total will be show...

Page 9: ...ARE mode as well You can cancel TARE function by pressing TR icon on display Note To cancel Parts Count by Weight Function you must go back to home page press on Parts Count by Weight and input 0 value in Parts Count table and press Next key Press Tare Input by Keypad icon Input TARE value and press Next icon Every load lifted will be calculated with TARE value Display will show TR icon on display...