General Instructions for Load Weight Calibration
Procedure
To initiate calibration of the load measurement process you must press “
Home
” icon, and on the Home
page press “
Calibrate
” icon.
- For the best results use at least minimum known calibration load weight of 30 to 50% of maximum lifting capacity of
the lift truck. Use customer floor scale or find a known load weight within the operational facility.
Important:
If you want the system to show load weight in pounds, use the known load weight in pounds and
enter that value accordingly. The same would apply if you want the system to show load weight
in kilograms.
( Have known load weight nearby)
Calibration
(
Note:
In our example a known calibration load weight is 4000.
)
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7
- Turn ignition switch to on position.
LCD display will show standard weighing mode.
- Tap on
Home
icon to get to the Home page
- To initiate system weighing calibration
tap on the “Calibrate” icon shown on Home page.
- In the Password menu input A123.
- Tap on Weighing icon
- Lower empty forks on the ground and follow instructions
(1 to 8) to calibrate scale and set overload alert.