MODE
Description
MODE 8
Represents standard “Weighing Cycle Mode”
MODE 0 to 6
Represents standard calibration mode
MODE 7
Represents “Overload Warning Setup Input”
MODE
Description
Action
Remarks
8
Standard “Weighing Cycle Mode”
Lower the forks to the
ground
MODE 8
must be
shown to initiate
the weighing cycle
0
Zeroing empty forks mode
Forks must be lowered
to the ground. Lift the
empty forks
Lift empty forks
just above the
ground
1
Enter first value of known load weight
0 – 9 numerical
increments, use
⇑
key
Press the “M” key
to advance to the
next MODE
2
Enter second value of known load
weight
0 – 9 numerical
increments, use
⇑
key
Press the “M” key
to advance to the
next MODE
3
Enter third value of known load weight
0 – 9 numerical
increments, use
⇑
key
Press the “M” key
to advance to the
next MODE
4
Enter forth value of known load weight
0 – 9 numerical
increments, use
⇑
key
Press the “M” key
to advance to the
next MODE
5
Enter fifth value of known load weight
0 – 9 numerical
increments, use
⇑
key
Press the “M” key
to advance to the
next MODE
6
Calibration mode with known load
weight on the forks
The forks must be on
the ground level. Lift
the forks with the
known load weight
After a few
seconds, the
display will show
the known load
weight value
7
Overload Warning Setup
Enter Overload
Warning Value as per
instructions described
above.
Applies only for
systems with the
overload warning
option
Summary of Contents for SkidWeigh ED2-EPT Series