IVDT SkidWeigh ED2-EPT Series Operating Instructions Manual Download Page 1

 

ED2-EPT Series 

SkidWeigh System 

Automatic Check Weighing for Electric Pallet Trucks 

 

 

 

 
 
 

 

Operating Instructions 

Weighing Loads 

Mounting Location 

Electrical Connections 

Pressure Transducer Installation 

Calibration Instructions 

Special Features

 

Accumulative Weight Loads Function 

Accumulative Weight Loads Function with Onboard Printer

  

 Mode Description 

Troubleshooting 

User’s Manual 

 
 
 
 

 

 

 

 

                             

Ver.0510-3- Software 2SD-1600

 

Summary of Contents for SkidWeigh ED2-EPT Series

Page 1: ...tions Weighing Loads Mounting Location Electrical Connections Pressure Transducer Installation Calibration Instructions Special Features Accumulative Weight Loads Function Accumulative Weight Loads Function with Onboard Printer Mode Description Troubleshooting User s Manual Ver 0510 3 Software 2SD 1600 ...

Page 2: ...hin 1 to 3 of the vehicle s lifting capacity Proper Operator Procedure for Weighing Loads To obtain load weight readout the indicator must show number 8 in the MODE display Insert the forks into the pallet or under the product to be weighed Make sure that the pallet is positioned all the way on the fork s carriage The number 8 in the MODE display must be shown before you initiate a Load Weighing C...

Page 3: ...fasten the digital indicator on the vehicle s dashboard Do not install indicator on removable cover that allows the access for service to the electric control compartment Anti vibration mount 20 UNC 25 x 20 mm vulcanized rubber Duro5 supplied with every kit Pressure Transducer Installation 1 The pressure transducer body itself has a male port 18 NPT Standard cable length is 6 1 5 meters 2 The pres...

Page 4: ...ble 2 Pressure Transducer RED WIRE of pressure transducer cable to RED WIRE of the seven wires cable from the indicator BLACK WIRE of pressure transducer cable to BLACK WIRE of the seven wires cable from the indicator WHITE WIRE of pressure transducer cable to WHITE WIRE of the seven wires cable from the indicator Digital Indicator Calibration Setup Keys Description Upper Right Key Labeled M Calib...

Page 5: ...wn load weight nearby to complete the calibration For best results use at least 30 to 50 known load weights of the particular lift truck s lifting capacity Example For 3000 pounds lifting capacity of the vehicle use at least 1500 pounds or close to that load weight Note If you want the system to show load weight in pounds use the known load weight in pounds and enter that value accordingly The sam...

Page 6: ...t the system is ready for zeroing the scale MODE Five Digits Load Weight Readout Display 0 To initiate the zeroing of the SkidWeigh the mode window must be showing 0 Lift the empty forks do not stop the lifting cycle until mode number changes from o to 1 Wait a few seconds the display will go blank and then it will show 0 or any other number in the furthest right digit display MODE Five Digits Loa...

Page 7: ... second digit from the right press the M key and the MODE digit will increment to 2 Keep pressing to enter a second value of known load weight Repeat this procedure until the MODE digit display is 5 Note Make sure that you enter 0 in MODE 5 since the known load weight has only 4 digits as in our example of 1500 MODE Five Digits Load Weight Readout Display 1 0 MODE 2 0 MODE 3 5 MODE 4 1 MODE 5 0 Be...

Page 8: ...splay will show the value of the calibrated known load weight System weigh calibration is completed From this point on the system weight calibration setup has been successfully done All calibrating parameters are saved and will not be lost when the power to the system is turned off or battery disconnected Digital display will show the load weight value until the forks are being lowered Display wil...

Page 9: ...arning to the operator that the Overload load weight has been reached Overload Warning Setup Procedure MODE 7 All ED2 EPT Series SkidWeigh s or other models with such overload warning feature require an additional step in the standard calibration procedure To enter the Overload Warning Value you must get to the MODE 7 This is automatic action To get to the MODE 7 the following is required Right af...

Page 10: ... 0 MODE 7 0 MODE 7 4 MODE 7 0 On the last shift Utilizing M key left shift the MODE 7 digit will turn off Mode 8 will be shown The Overload Weight Value of 4000 has been stored in the memory It will be shown briefly on the digital display and the unit will return to the measurement MODE 8 MODE Five Digit Load Weight Readout Display 4 0 0 0 MODE 8 The Overload Warning Value has been successfully st...

Page 11: ...utton This will reset the current total and the cycle will start all over Right Button Reset Note Weight loads can be added only while the indicator shows the load weight If the load weight is lowered and Mode 8 is shown on the display the last load weight will not be added even if the left button is pressed The maximum number of load weights entered into the accumulative counter is 40 If 40 loads...

Page 12: ...unter At any point you can obtain a ticket for all entered load weights stored in the load weighing counter by pressing the right button The printout will show all individual load weights and total weight As soon as you lower the forks and the last load weight is no longer on the display the system will be RESET Example of two load weights added in the weighing counter and being printed IVDT SkidW...

Page 13: ...r NCI Mini Printer Series is for 12 V DC operation Printer can be powered only through IVDT Inc wiring harness since power from the vehicle can be anywhere from 12 to 55V DC Only through original wiring harness the printer will get 12 V DC from the ED2 SkidWeigh Series Digital Indicator regardless of the vehicle voltage Consult printer User s Manual for installing the paper printer ribbon etc ...

Page 14: ...ht 0 9 numerical increments use key Press the M key to advance to the next MODE 3 Enter third value of known load weight 0 9 numerical increments use key Press the M key to advance to the next MODE 4 Enter forth value of known load weight 0 9 numerical increments use key Press the M key to advance to the next MODE 5 Enter fifth value of known load weight 0 9 numerical increments use key Press the ...

Page 15: ...h is turned ON The pressure transducer is near saturation 2 45V The load weight is too heavy for this vehicle Pressure transducer damaged When the known load weight is lifted there is a larger weight readout error Follow a proper weighing cycle Calibration required Faulty pressure transducer Recalibrate the system with known load weight The system is calibrated in kilograms but the operator thinks...

Page 16: ... you initiate a Load Weighing Cycle Activate lift control valve and start lifting the load Do not stop lifting cycle until the load weight is shown on digital display As soon as the load has been lifted digital display on the indicator will go blank for a moment and then the weight value of the lifted load will be displayed This load weight value will be displayed on the indicator As soon the fork...