Calibration Starting Point For All Of The ED2 Series SkidWeigh Systems
---------------------------------------------------------------------------------------
Lower the empty forks to the ground. There should be no hydraulic pressure in lift hydraulic circuit.
- Turn ignition switch to on position (electric lift trucks) and start the engine on combustion powered lift trucks
- LED display will show software version briefly on the right side and number
8
will be shown in the
Mode
digit.
---------------------------------------------------------------------------------------
1. Calibration of empty forks lifted just above the ground
To initiate calibration press the
“M”
key (use a paper clip) and hold it down for approx. 5 seconds.
After 5 seconds the Mode display digit will change from number
8
to
0
.
System is ready for automatic zeroing of the scale function
When LED display is showing
“0”
in
Mode
digit, lift the empty forks ( or attachment such as longer forks, clamp, etc)
just above the ground.
Note:
Activate the lift control valve as you would do during the normal lifting operation. Do not lift the empty forks slowly.
Wait few seconds, LED display will go blank and will show
Mode
digit 1
and
default
“0”
value in furthest right digit
display.
(The
“0”
value in furthest right digit might be some other number if calibration done previously with different load weight)
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7