Important:
If you want the system to show load weight in pounds, use the known load weight in pounds and
enter that value accordingly. The same would apply if you want the system to show load weight in kilograms.
Use the known load weight in kilograms and enter that value into the system accordingly.
Digital Indicator
(Calibration and two keys description)
- Upper right button
“M”
is used to enter calibration mode and to shift left to the next digit.
- Lower right button
“Arrow Up”
is used to enter numerical increments from 1-9, wrap around.
- Both buttons are used during the system calibration.
- Buttons can be accessed through two small holes on the cover.
- Use paper clip to activate buttons. Do not push buttons too hard!
- Left most significant digit represents
Mode of operation
.
- Other five digits represent the load weight readout.
Mode LED Digit Five Digits Load Weight Display
MODE
Digit 5
Digit 4
Digit 3
Digit 2
Digit 1
-
Note:
- Every time the power is applied the software version will be shown momentarily for a brief moment.
- When forks are lowered to ground LED display will show
Mode 8
. This is a starting point to take load weights.
- For best results during weight calibration use at least 30 to 50 % of known lad weight of the vehicle lifting capacity.
- If you make a mistake during the system calibration, turn power ON / OFF and start all over.
- If the power to the system is disconnected calibration information / set up information
will not be lost
.
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7