At this point you must lower the empty forks to the ground. The LCD display will show
At this point you must pick up a known load weigh and
lower the loaded forks to the ground
.
( Our example of the known load weight is 2000 kg)
Enter the known load weight of 2000 into the LCD display and press
“Enter key”
↵
. The LCD display will show
At this point
lift loaded forks just above the ground
. After few seconds the calibrated load weight value of of 2000 will
be stored in the system memory and the LCD display will go back to showing date and time.
Calibration of the ED3 & ED4-AT system weighing function is finished.
LCD Display
CALIBRATION 1
WEIGHT =
❏
LCD Display
CALIBRATION 1
WEIGHT = 2000
LCD Display
CALIBRATION 1
LIFT LOAD
LCD Display
CALIBRATION 1
LOWER FORKS
LCD Display
AUG 28, 2010
12:25:23
Integrated Visual Data Technology Inc. 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7