background image

 

11 

FUSE Replacement: 

The fuse use on MT608 is: 

BUSSMANN 

Fast Acting, Glass Tube 

Rating: 250VAC, 1A 

Size: 5x20mm 

Warning: 

1.

 

Make sure the power off before 

replace the fuse. 

2.

 

Do not replace the fuse with a 

different rating fuse. 

 

2.2.2 Grounding Requirements 

 

Chassis ground must be used. DC ground is not directly coupled to Earth ground 

internally. It is preferable not to ground DC negative return to chassis ground as poor site 

earths can introduce noise into a system, but if necessary an earth connection should be made, 

from the power supply return point to the central star earth point. Ground conductors should be 

as short and as large in size as possible. The conductors must always be large enough to carry 

the maximum short circuit current of the path being considered. Ground conductors should be 

connected to a tree from a central star earth ground point. This ensures that no ground 

conductor carries current from any other branch. 

 

 

 

2.2.3 CE Requirements 

To make an NP-612S comply with EMC directives, and to reduce susceptibility to electrical 

interference, a separate #14 AWG ground wire should be taken to the chassis ground terminal 

of the power connector. This ground connection should be run directly to the central star earth 

connection point (as recommended in most Installation Instructions). 

 

2.2.4 Safety Guidelines 

This section presents recommended installation practices, and procedures. Since no two 

applications are identical, these recommendations should be considered as guidelines. 

 

Hardware Considerations  WARNING! 

The system designer should be aware that devices in Controller systems could fail and thereby 

create an unsafe condition. Furthermore, electrical interference in an operator interface, such 

Summary of Contents for NP-612S

Page 1: ...NP 612S RISC based operator interface terminal with 12 1 flat panel display User s Manual ...

Page 2: ...onnections 13 2 3 1 Connector COM 1 RS232 13 2 3 2 Connector COM2 RS232 COM3 RS485 and COM3 RS232 14 2 3 3 Serial Port Settings 15 2 3 4 USB Master port 16 2 4 Dip Switch 17 2 4 Dip Switch 17 2 5 CE Requirements 18 2 6 Dimensions of NP 612S 19 Chapter 3 Windows CE NET 20 3 1 Introduction 20 3 2 Utilities 20 3 2 1 Soft Keyboard 20 3 2 2 System Settings 21 3 2 3 NORFlash 25 3 2 4 Startup 25 3 2 5 Re...

Page 3: ...3 3 4 2 NP 612S SDK 32 ...

Page 4: ... thus subject to change without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of IVC Displays Inc Information provided in this manual is intended to be accurate and reliable However IVC Displays Inc assumes no responsibility for its use nor for any infringements upon the rights of third parties whic...

Page 5: ...amage to equipment with the symbol shown to the left A Warning symbol indicates that the reader should pay special attention to the accompanying text Precautionary steps should be taken to insure that the installation is in compliance with warnings Warnings include hazardous conditions that could cause personal injury or equipment damage if care is not taken The text next to this symbol describes ...

Page 6: ...k fill and hardware line draw operations The graphics accelerator is used in the system to off load graphics operations from the processor Features Built in flash memory and Windows CE OS inside All in one platform the CPU DRAM and Windows CE are integrated Low power consumption and Fan less NEMA 4 IP65 compliant front panel One CompactFlash slot Audio Ethernet port 10 100Base T 1 2 Specifications...

Page 7: ...m 0 246 x 0 246 Viewing angle 100 Upper Lower 120 Left Right Luminance cd m2 250 Storage temperature C 20 60 Operating temperature C 0 45 Backlight CCFLx1 Contrast ratio 200 1 Touch screen Type 4 wire analog resistive Resolution continuous Light transmission above 80 Life 1 million activation minimal Environmental Specifications Operating temperature 0 45 C 32 113 F Relative humidity 10 90 40 C no...

Page 8: ... mounted on the front panel of a steel enclosure through an appropriate opening Allow a clearance of 1 25mm around the sides of the unit for mounting hardware Allow clearance for cable connections to the back of the unit Unit depth may vary according to cable type used Typically plan a depth to accommodate at least 1 72 51mm behind the panel NEMA 4 Mounting Put the unit through the panel cut out S...

Page 9: ...hould not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to determine which codes apply ...

Page 10: ...ions Caution Supply Voltage Condition Do not power the NP 612S and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 VDC output from some controllers may not have enough current to power the NP 612S Caution Wire Routing Wire lengths should be minimized Maximum 1600 500 m shielded 1000 300 m unshielded Wires should be run in pairs with a neutral or commo...

Page 11: ...ng considered Ground conductors should be connected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an NP 612S comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the chassis ground terminal of the power connector...

Page 12: ...ut down procedure to ensure safety of personnel ICS 3 304 81 Safety Recommendations Consideration should be given to the use of an emergency stop function which is independent of the programmable controller Where the operator is exposed to the machinery such as in loading or unloading a machine tool or where the machine cycles automatically consideration should be given to the use of an electromec...

Page 13: ...aution Restrict cable length to less than 500 150m for RS485 422 devices and 50 15m for RS232 devices to avoid communications problems Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near sources of electrical noise Be sure that the cable ends have been inserted all of the way into mating connectors and are...

Page 14: ...ee section 2 3 3 Serial Port Settings COM3 RS 485 connect RS 485 2 wire Device NP 612S COM1 RS 485 9P D SUB Female RS 485 2 wire Device 6 Data Data 9 Data Data 5 GND COM3 RS 485 connect RS 485 4 wire Device NP 612S COM1 RS 485 9P D SUB Female RS 485 4 wire Device 1 Rx Tx RS485 Transmit 2 Rx Tx RS485 Transmit 3 Tx Rx RS485 Receive 4 Tx Rx RS485 Receive 5 GND ...

Page 15: ...e how to configure the COM1 COM2 COM3 serial ports 1 From the Windows CE desktop execute CECP 2 Scroll to the Set Serial Port Mode tab Set COM1 to the desired mode 3 Set COM1 to the desired mode 4 Scroll to the Save registry tab and save the registry ...

Page 16: ...aster port The USB Master port can connect USB mouse and USB keyboard The USB Master port support USB 2 0 full speed host 12Mbps This port support USB Mass storage device But the USB hard disk must use external power ...

Page 17: ...the center of the until it moves The moves to upper left lower left lower right and upper right corners When all five are done the will disappear The Touch Screen parameter will store at Flash Rom Boot Loader mode Load new Windows CE image file If the NP 612S already load the CE image with boot loader Set the DIP SW3 ON then power ON into boot loader mode Refer the load Win CE image document ...

Page 18: ...atisfactorily in electromagnetic noise immunity and without emitting high levels of electrical noise into the environment emission The units are designed to meet European Community standards when installed per the wiring instructions in this manual Compatibility Standards The NP 612S has been designed to meet electromagnetic compatibility for industrial environments CISPR EN 55011 Group 1 Class A ...

Page 19: ...19 2 6 Dimensions of NP 612S Cutout dimensions NP 612S 305mm 12 1 W x 231mm 9 09 H ...

Page 20: ...onment Windows CE NET contains everything you need to create a custom Windows CE based device that requires rich networking hard real time and a small footprint as well as rich multimedia and Web browsing capabilities 3 2 Utilities There are several useful utilities built in the standard Windows CE OS of NP 612S 3 2 1 Soft Keyboard The NP 612S is dedicated to the small sized operator interface It ...

Page 21: ...s an integrated utility for users to make basic setting of the machine Step 1 Tap the cecp icon from Desktop 2 Launch the System Settings Control Panel Touch Screen settings The touch screen calibration can be executed from the Control Panel ...

Page 22: ...The Touch Screen parameter will store at Flash Rom Backlight LCD Settings page of the cecp provides the function to turn off the LCD backlight and thus elongates the period of service For example if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used The user must select 10 minutes in the put down box and then press OK button Then the screen sa...

Page 23: ...23 On the other hand if users want to disable the screen save function select Never and press OK button ...

Page 24: ...older Next time reboot the NP 612S Windows CE system will use the stored registry data System version Show current CE image version Set serial port mode Set Com1 mode Select RS232 RS485 2wire or 4wire mode Set Com3 RS232 RS485 mode The serial port mode can be saved by Save registry HOME Directory Change This can set the Web Server directory Must reboot HMI ...

Page 25: ...ecution function would automatically perform This function is useful for control system to do the initialization processes or some other programs Step1 Create startup directory in NORFlash Step2 Copy executable files or Shortcut to Startup directory which is created in Step 1 An alternative way to setup startup files is to make a shortcut and copy it to NORFlash StartUp A shortcut can execute a pr...

Page 26: ...ection Use Remote Desktop Connection you can remotely control your computer To use Remote Desktop you need the following Windows XP Professional installed on your office computer or whichever computer you plan to operate remotely This computer is known as the host You must first enable the Remote Desktop feature on your office computer so that you can control it remotely from another computer You ...

Page 27: ...og box type your user name password and domain if required and then click OK The Remote Desktop window will open and you will see the desktop settings files and programs that are on your office computer Your office computer will remain locked Nobody will be able to work at your office computer without a password nor will anyone see the work you are doing on your office computer remotely Note To ch...

Page 28: ... up Connections 3 Find the default device name Change it to a unique one depending on the plan of individual LANs CS89501 4 If the NP 612S is a node of a LAN with DHCP servers it is now available 5 If the NP 612S is a node of a LAN with fixed IP server please consult with MIS to get specific IP address Click Start Settings Control Panel Double click Network and Dial up Connections and update the I...

Page 29: ... 1 Make sure the Microsoft ActiveSync service is properly installed on the host PC Microsoft ActiveSync 2 Click the Connection Settings 3 Allow serial cable or infrared connection to this COM port 4 Connect the MT 612S Com1 RS232 and PC RS232 by the RS232 ActiveSync cable ...

Page 30: ... your NP 612S with your desktop computer 7 Now you can synchronize the information between the NP 612S and host computer with ActiveSync 3 3 3 Web browser The NP 612S built in Windows CE OS includes Microsoft Pocket Internet Explorer It can be used to browse web pages on World Wide Web via LAN or dial up connection ...

Page 31: ...e code level Users must rebuild the runtime file for a different Windows CE platform even though the source code may not be changed at all The following development tools must be installed on the PC Microsoft eMbedded Visual C 4 0 Microsoft eMbedded Visual C 4 0 Service Pack 1 NP 612S SDK 3 4 1 Microsoft eMbedded Visual C 4 0 System Requirements To use Microsoft eMbedded Visual C 4 0 you need the ...

Page 32: ...evelopers with access to an extensive set of functions that are specific to the NP 612S hardware Step Installing the MT612S SDK 1 Download or from NP 612S SDK CD find the EP931X_SDK msi file Double click the file s name start the Setup Wizard 2 The installer will be prompted for acceptance of a license agreement Following that the SDK should install itself automatically on the host machine without...

Page 33: ...t PCL language printer You can connect a PCL printer at USB Host port or via Network connect to a shared printer From Internet Explorer or user s application menu click File Page Setup will appear print setup dialog After the Page Setup click File Print printer will print out the data ...

Page 34: ...34 Desktop PC shares the printer ...

Page 35: ...35 ...

Reviews: