Aero 60/90
Installation
Instructions
1.2
Release 2.0
PAGE 8
1.2.3
Connecting to Air Supply
The machine requires clean, dry air. Minimum requirement:
- 6 bar (85 psi)
- 5 cfm
Air connection is to quick disconnect adapter (included) or to ¼ NPT female thread.
1.2.4
Setting Pressure Regulator
Adjust system pressure to 6 bar (85 psi) by lifting the adjusting knob to unlock, then turning the knob
clockwise to increase the pressure or counterclockwise to decrease the pressure. Push down on the
adjusting knob to lock the regulator after making adjustments.
1.2.5
Flow Controls
The
Flow Controls
are used to adjust the speed of the pad movement.
I/O connections
Flow forward
Flow backward
Flow up
Flow down