SM Shockless Static Neutralizing Bars
6. MAINTENANCE
NOTE
–
Only qualified service personnel are to perform maintenance tasks.
NOTE
–
Never use hard or sharp objects to scrape ionization points.
CAUTION – ELECTRICAL SHOCK HAZARD
De-energize all power supplies before performing any maintenance tasks.
CAUTION – FIRE HAZARD
Never energize a power supply with any trace of alcohol remaining on
the equipment. Dust or dirt around the ionization points will reduce
the effectiveness of the static bar. The ionization points must be cleaned
periodically to prevent deposits from accumulating:
1. De-energize all power supplies before performing any maintenance tasks.
2. Allow a gentle flow (5-10 psig) of compressed air through all RSM bars during
maintenance.
3. Use dry compressed air to remove loose particulate from the static bar. If it is
very dirty, it may be necessary to remove the static bar from its mounting and
turn it upside-down while using compressed air to clean. A soft brush with
plastic bristles may be used as well.
4. Press a soft pencil eraser onto each point and gently twist to remove any buildup
from the ionization points.
5. Wipe ionization points with isopropyl alcohol applied to a clean dry cloth to
remove ink or resistant coatings.
NOTE
–
The alcohol must not contain additives. Do not pour alcohol
directly onto the bars, and do not soak the static bar or any of its components
in alcohol.
CAUTION – FIRE HAZARD
Ensure all traces of alcohol have been removed and the static bar is completely
dry before energizing the power supply.
7. REPLACEMENT PARTS
Part Number
Description
5050970
Mounting Kit, SM Bar (contains 2 brackets and hardware)
5050001
SLCC HV Connector Kit
4670204
Cleaning Brush
4000004
Static Bar Checker