4
5200767 Rev. F
SM Shockless Static Neutralizing Bars
Mounting Power Supplies
Mount power supplies to the machine frame (preferably away from operator contact)
or to a nearby wall or post.
Installing High Voltage Cables
1. Route the high voltage cables attached to each static bar along the machine
frame or wall to the power supply.
2. Install spring loaded cable connectors on the free end of each cable, as described
on the enclosed SL instruction sheet.
3. Ensure that the power supply is de-energized, and then remove the protective
plastic plug from the power supply high voltage connection by gently prying
with an insulted screwdriver.
4. Insert the cable (with spring loaded connector attached) into the power supply
high voltage connection. Screw in the knurled plug to secure the cable.
NOTE – FINGER TIGHTEN ONLY
CAUTION – FIRE HAZARD
Ensure that the right-angled cable end of the SM Static Bar is at least 3/8”
from grounded objects.
5. OPERATION
Before energizing any power supply
1. Ensure that all power supplies are properly grounded.
2. Ensure that all static bars are properly grounded.
3. Ensure that all static bars have been properly located, positioned and installed.
After the above checks have been performed, simply energize each power supply to
operate the static neutralizing bars.