5200767 Rev. F

SM Shockless Static Neutralizing Bars

The SM and RSM static neutralizing bars are shockless bars with capacitively 

coupled ionization points.  The capacitively coupled design provides a safety feature 

that prevents hazardous electrical shocks if there is contact with the ionizing pins.  

This safety feature does not compromise the static bar’s performance.  The RSM bar 

has the same features as the SM bar but is equipped with an integrated compressed 

air tube that extends its range and reinforces the bar.
The S165S and S265S power supplies are rated at an output of 5,000 Volts.  Their 

current limiting design assures a maximum short-circuit current of only 5 mA, 

providing an additional safety feature that further prevents hazardous electrical 

shocks if there is contact with the ionizing pins.

Receipt of Equipment

1.   Carefully remove the equipment from its carton.
2.   Inspect contents for damage that may have occurred during shipment.  If any 

damage has occurred, the local carrier should be notified at once.  A report 

should be forwarded to Simco-Ion, 2257 North Penn Road, Hatfield PA 19440.

3.   Empty the carton to ensure that small parts are not discarded.

Return Shipments

Prior to returning goods, contact a Sinco-Ion Customer Service Representative for 

a Return Authorization Number.  This number should be included on the packing 

list.  All correspondence should also reference the Return Authorization Number.  

Any item being returned should be shipped prepaid and packed to provide adequate 

protection.

3.  SPECIFICATIONS

SM Bar Bar

Operating Voltage

5 kV 

Operating Temperature 110˚F (43˚C), max; humidity 70% RH, mas (no dewing permissible)
Dimensions

3/8”W x 3/8”H [9.525 x 9.525 mm] 

Material

Casing: aluminum, inner bar: GE Valox (PBT), emitter points: stainless steel (type 302)

Power Supply

S165S

S265S

Input Voltage

120V

230V

Frequency

50/60 Hz

50/60 Hz

Output Ports

2

2

Capacity (bar + cable 

combined length)

420”

420”

Summary of Contents for Simco-Ion S165S

Page 1: ...5200767 Rev F SM Shockless Static Neutralizing Bars INSTALLATION AND OPERATING INSTRUCTIONS SM Shockless Static Neutralizing Bars with S165S S265S Power Supplies ...

Page 2: ...ETYWARNINGS 1 2 DESCRIPTION 1 Receipt of Equipment 2 Return Shipments 2 3 SPECIFICATIONS 2 4 INSTALLATION 3 Grounding 3 Mounting Static Neutralizing Bars 3 Mounting Power Supplies 4 Installing High Voltage Cables 4 5 OPERATION 4 6 MAINTENANCE 5 7 REPLACEMENT PARTS 5 8 WARRANTY 6 ...

Page 3: ... neutralizing equipment Avoid touching static neutralizing bar when power supply is energized CAUTION FIRE HAZARD Do not install or operate equipment in close proximity to any flammable solvents CAUTION FIRE HAZARD Ensure that the right angled cable end of the SM Static Bar is at least 3 8 from grounded objects 2 DESCRIPTION The S165S and S265S power supplies are designed as a power source for the...

Page 4: ...e equipment from its carton 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred the local carrier should be notified at once A report should be forwarded to Simco Ion 2257 North Penn Road Hatfield PA 19440 3 Empty the carton to ensure that small parts are not discarded Return Shipments Prior to returning goods contact a Sinco Ion Customer Service Represe...

Page 5: ...etal machine frame or connect a heavy copper wire from the ground terminal of the power supply to a well grounded electrical conduit or water pipe Mounting Static Neutralizing Bars 1 Place each static bar so that it extends across the width of the material to be neutralized For SM Static Bar with right angled cable end ensure cable end is at least 3 8 from grounded machine frame 2 The bar s ioniza...

Page 6: ...ug from the power supply high voltage connection by gently prying with an insulted screwdriver 4 Insert the cable with spring loaded connector attached into the power supply high voltage connection Screw in the knurled plug to secure the cable NOTE FINGER TIGHTEN ONLY CAUTION FIRE HAZARD Ensure that the right angled cable end of the SM Static Bar is at least 3 8 from grounded objects 5 OPERATION B...

Page 7: ... compressed air to remove loose particulate from the static bar If it is very dirty it may be necessary to remove the static bar from its mounting and turn it upside down while using compressed air to clean A soft brush with plastic bristles may be used as well 4 Press a soft pencil eraser onto each point and gently twist to remove any buildup from the ionization points 5 Wipe ionization points wi...

Page 8: ... tampered with misused improperly installed altered has received damage through abuse carelessness accident connected to improper line voltage or has been serviced anyone other than an authorized factory representative The warranty does not apply when Simco Ion parts and equipment have been energized by other than the appropriate Simco Ion power supply or generator or when a Simco Ion power supply...

Reviews: