background image

3

PINNER APPLICATORS

5200647 Rev G

1. SAFETY

NOTE

 – Statements identified with a NOTE indicate precautions necessary 

to avoid potential equipment failure.

CAUTION

 – Statements identified with a CAUTION indicate potential  

safety hazards.

The following safety procedures must be followed for safe Pinner operation.
1.  Read instruction manual before operating or installing device.
2.  Qualified service personnel must do installation and repairs.
3.  Turn off power supply before cleaning, adjusting or servicing the Pinner 

applicator.

4.  Do not install or operate Pinner applicators close to flammable materials, 

solvents or gases.  These materials may ignite.

5.  Do not touch the head of the Pinner applicator during operation.
6.  All metal parts near the Pinner applicator, including the frame of which it is 

mounted, must be electronically grounded or shock may result.

7.  Provide proper grounding for the power supply (refer to power supply 

instruction manual) and the flex arm, if used.

2. INTRODUCTION

Simco-Ion’s  Pinner Series static charge applicators consists of the Linear Pinner, 

5-Point and Pinner Claw.  Pinner applicators are arc-resistant to avoid suspension 

of static charge and loss of pinning action. The Pinners are current limited to ensure 

operator and equipment safety.
Arcing can cause a multitude of problems such as EMI interference, shutdown 

of production lines and personnel injury due to surprise from electrical shock.  

Resistance to arcing means that the Pinner applicators continuously supply static 

charge.  This feature makes them easier and safer to set up and use. The Pinner 

also produces superior bonding compared to less sophisticated applicators.  The 

applicators are also available in a non-current limited version for less sensitive areas.

Features and Benefits

•  Current limited design for operator and equipment protection
•  Arc condition sensing and instantaneous intervention resulting in uninterrupted 

pinning action

•  Minimized EMI and RFI generation, preventing disruption of sensitive 

controls

•  Optional manual adjust gooseneck with easy lock/release feature and insulative 

brackets

Summary of Contents for Simco-Ion Pinner Series

Page 1: ...PINNER APPLICATORS 5200647 Rev G Pinner Series Arc Resistant Pinner Applicators INSTALLATION AND OPERATING INSTRUCTIONS ...

Page 2: ...nefits 3 How Pinners Work 4 Receipt of Equipment 4 Return Shipments 4 3 SPECIFICATIONS 5 4 INSTALLATION 5 Standard Installation 5 Installation with Optional Mounting Stand P N 5051082 6 High Voltage Wire Routing 6 5 OPERATION 8 6 MAINTENANCE 8 7 TROUBLESHOOTING 8 8 REPLACEMENT PARTS 9 9 WARRANTY 9 ...

Page 3: ... the flex arm if used 2 INTRODUCTION Simco Ion s Pinner Series static charge applicators consists of the Linear Pinner 5 Point and Pinner Claw Pinner applicators are arc resistant to avoid suspension of static charge and loss of pinning action The Pinners are current limited to ensure operator and equipment safety Arcing can cause a multitude of problems such as EMI interference shutdown of produc...

Page 4: ...r to ground depending upon the setup Receipt of Equipment 1 Carefully remove the equipment from the carton 2 Inspect contents for damage that may have occurred during shipment If any damage has occurred during shipment the local carrier should be notified at once A report should be forwarded to Simco Ion 2257 North Penn Road Hatfield PA 19440 and 215 822 6401 3 Empty the carton to insure that smal...

Page 5: ... kV 1 min Current Limit 30 kV input 375 µA 50 kV input 625 µA Short Circuit Pin to Ground at 30 kV Input Non Repetitive 2 second maximum no damage Weight 0 65 lbs 4 INSTALLATION NOTE To install pins into Pinner Claw 1 Push blunt end of pin into head s socket 2 Rotate pins until desired ion pattern is produced Standard Installation Two mounting clamps and hardware are standard with each Pinner appl...

Page 6: ...o publication 5101223 attached with optional mounting stand kit and Figure 4 for additional assembly details 1 Remove two cap screws with 3 16 hex key and magnet from base of mounting stand 2 Remove cable strain relief from base of mounting stand 3 Insert pinner applicator Linear Pinner Pinner 5 Point or Pinner Claw by fully straightening the flexible arm and routing the cable assembly through its...

Page 7: ...law products are rated for use with up to 30kV or 50kV in special installations with insulation required Use at high voltages may cause component breakdown and operator shock hazard Figure 1 Mounting Using Perforated Strips Figure 2 Mounting Using Plate Figure 3 Mounting Using Plate ...

Page 8: ...tically charged and adhere to each other or to ground depending upon setup Pinner applicators are designed for use where EMI RFI affects sensitive controllers Loss of pinning action is detrimental to the product or operation Operators may come into contact with materials 6 MAINTENANCE Pinner applicators require simple maintenance procedures Clean the applicators periodically with isopropyl alcohol...

Page 9: ... purchaser to Simco Ion 2257 North Penn Road Hatfield PA 19440 transportation prepaid and insured for its replacement cost Prior to returning any goods for any reason contact Simco Ion Customer Service at 215 822 6401 for a Return Authorization Number This number must accompany all returned items This warranty does not apply when the equipment has been tampered with misused improperly installed al...

Page 10: ...10 PINNER APPLICATORS 5200647 Rev G Simco Ion 2257 North Penn Road Hatfield PA 19440 215 822 6401 800 203 3419 www simco ion com customerservice simco ion com 2021 Simco Ion Printed in the U S A ...

Reviews: