5
IQ Power Fantom HL
5201305 Rev A
Blower Motor Wiring
The Fantom HL blower requires 115 VAC 60 Hz. Connect the line cord as shown
in Fig. 1.
Figure 1. Motor Schematic and Wiring Diagram
NOTE
– Do not attempt to operate at voltages other than those specified.
NOTE
– Starting current for blower motor is approximately 5x the motor
nameplate running current. The blower motor power source, including
step-down transformer if used, must be capable of supplying starting
current without excessive voltage drop for proper blower motor operation.
If available starting current is insufficient, blower motor will operate
continuously at greatly reduced RPM, drawing excessive current and
overheating. This may result in damage to the blower motor.
WARNING – Electrical Shock Hazard
Electrical installation and repairs must be performed by a skilled electrical
engineer according to the applicable national and local regulations. The
equipment must be properly grounded. Grounding is required to ensure
safe and proper operation and to prevent electrical shocks upon contact.
WARNING –
All regulatory listings and approvals do not apply when the
motor is operated on VFD (Variable Frequency Drive) power.
• Connect motor’s BLACK
and YELLOW leads
together to 115V HOT
(typically black wire)
• Connect motor’s PURPLE
lead to 115V NEUTRAL
(typically white wire)
• Connect motor’s BLUE
and RED leads together
• Connect motor’s GREEN
lead to GROUND
(typically green, green-
yellow, or bare wire)
10A typ.
1.9A typ.