Ion Balance
1. Balance is set at the factory.
2. Balance may be evaluated using a charged plate monitor such as the Simco-
Ion CPM. The plate should be placed at the typical operating distance for
testing and adjustment. Static charges in the vicinity of measurement will affect
reading, remove or neutralize static charges in the vicinity before taking ion
balance measurements.
3. If anything other than an even balance is required, the balance can be manually
adjusted through the Control Station. Set the power supply to Manual Mode
and adjust the balance as necessary to neutralize charge.