LN-9245-00.6
Air Heater Assembly - Installation
7
7
7
7
7
LOCA
LOCA
LOCA
LOCA
LOCATION
TION
TION
TION
TION
INST
INST
INST
INST
INSTALLA
ALLA
ALLA
ALLA
ALLATION
TION
TION
TION
TION
Install the air heater near the applicator, but in an
area outside of the hazardous location. The unit
should be located so that it is not exposed to water,
paints or solvents, and high temperatures. (The
ambient temperature should not exceed 120
°
F.)
INPUT POWER
INPUT POWER
INPUT POWER
INPUT POWER
INPUT POWER
Input supply voltage connection should be made
from a fused disconnect. Route the input power
wires through the side of the cabinet. Generally,
conduit should be used for the input power.
(Always comply with national and local electrical
codes.)
PNEUMA
PNEUMA
PNEUMA
PNEUMA
PNEUMATIC
TIC
TIC
TIC
TIC
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
Use appropriate size piping to connect the air
heater to a filtered inlet source. The air heater
compressed air input is at the bottom of the unit
and is identified as "IN". Connect the heated air
output located at the top of the unit identified as "hot
outlet pipe" to the coating applicator(s) using 1/2-
inch OD, nylon 11/12-inch tubing, with proper
pressure rating.
A secondary sensing air supply must be connected
to the pressure switch [8] through 1/4-inch OD
tube fitting [29].
If the unit is being wired directly to the PLC
electrical connections, the pressure switch must
be by-passed. (Refer to "Figure 1: Installation
Options" for assistance.)
>
The air heater cabinet must be proper-
ly connected to earth ground.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
Do not locate the unit near or adjacent
to heat producing equipment such as
oven, high wattage lamps, steam pipes,
etc.
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
C A U T I O N
!!!!!
>
The air heater MUST
MUST
MUST
MUST
MUST be located
outside
outside
outside
outside
outside of any hazardous area(s)
as
close to applicator as possible.
(See
NFPA-33.)
>
This manual must be read and thor-
oughly understood by ALL
ALL
ALL
ALL
ALL personnel who
operate, clean, or maintain this equipment.
Special care should be taken to ensure
that the WARNINGS
WARNINGS
WARNINGS
WARNINGS
WARNINGS and requirements
for operating and servicing are safely
followed.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
>
All hardware and tubing used between
the air heater and applicator must have
proper working pressure (150 psig) and
temperature (150
°
F) ratings.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!